Beretta Mynute Sinthesi 25 C.S.I. Manual De Instalación Y De Uso página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
ENGLISH
g)
that the fuel supply system has the correct capacity for the neces-
sary capacity to the boiler and that it has all the safety and control
devices prescribed by current regulations.
4.2 Appliance ignition
At the fi rst ignition, in case of prolonged inactivity and in case
of maintenance intervention, before starting the appliance, it is
essential to create a head of water and make sure that the con-
dense evacuates correctly.
Fill the condensate trap with pouring about 1 liter of water in the boiler
combustion analysis outlet and check:
- the fl oating of the safety shutter
- the correct fl ow of water from the outlet pipe to the boiler outlet
- sealing of the condensate drain connection line
A correct functioning of the condensate discharge circuit (siphon and
pipes) requires that the condensation level does not exceed the level of
the siphon.
To start up the boiler it is necessary to carry out the following operations:
- power the boiler
- turn on the gas tap to allow fuel fl ow
- set the room thermostat to the required temperature (~20°C)
- turn the mode selector to the required position:
Winter: turn the function selector in the area marked with + and - (fi g.
24b) to obtain DHW and heating. In case of a heat request, the boiler
will switch on and the digital display will show the temperature of the
heating water, the heating mode icon and the fl ame icon (fi g. 25).
In case of a request for domestic hot water, the display (fi g. 3 - 2) will
show the temperature of the domestic water, the DHW mode icon and
the fl ame icon (fi g. 26).
Adjustment of the heating water temperature
To adjust the heating water temperature, turn the knob with the
symbol (fi g. 27) clockwise in the area marked with + and -.
Summer: turn the selector onto the summer symbol
activate the traditional function of domestic hot water only. In the case
of a request for domestic hot water, the display will show the temper-
ature of the domestic water, the DHW mode icon and the fl ame icon
(fi g. 26).
Pre-heating (faster hot water): turn the domestic water temperature ad-
justment knob (fi g. 29) onto the
function. The display will show the fi xed
hot water temperature adjustment knob back to the required position.
This function keeps the water in the domestic hot water exchanger hot,
to reduce standby times when a request is made. The display indicates
the outlet temperature of the heating water or the domestic hot water
based upon the request in progress. During burner ignition following a
pre-heating request, the display shows the fl ashing
fl ame icon (fi g. 30). To deactivate the pre-heating function, rotate the
domestic hot water temperature adjustment knob back to the symbol
. Bring the domestic hot water temperature adjustment knob back to
the required position. This function cannot be activated when the boiler
is OFF: function selector on
Adjusting the domestic hot water temperature
To adjust the domestic water temperature (bathrooms, showers, kitch-
en, etc.), turn the knob with the
with + and -. The boiler remains in standby until the burner ignites in
response to a heat request. The display shows the domestic water
temperature, the DHW mode icon and the fl ame icon (fi g. 26). The
boiler continues to function until the temperatures set on the boiler are
reached, or the heat request terminates; it will then go back to standby.
If the digital display shows the
the boiler is in a temporary stop condition (see the "Operating status
and faults" chapter) (fi g. 31).
Environment Automatic Adjustment System function (S.A.R.A.)
By setting the heating water temperature selector in the area marked
with AUTO (fi g. 32) (temperature value from 55 to 65°C), the S.A.R.A.
self-adjusting system is activated: the boiler varies the delivery tem-
perature according to the closing signal of the ambient thermostat.
When the temperature set with the heating water temperature selec-
tor is reached, a 20-minute count begins. If the ambient thermostat
8
MAX
(fi g. 24a) to
symbol to activate the pre-heating
symbol. Bring the domestic
symbol and the
OFF (fi g. 34).
symbol (fi g. 28) in the area marked
icon and an alarm code, this means
still requests heat during this period, the value of the set temperature
automatically increases by 5°C. When the new value is reached, an-
other 20-minute count begins. If the ambient thermostat still requests
heat during this period, the value of the set temperature automatically
increases by 5°C. This new temperature value is the result of the tem-
perature set manually with the heating water temperature selector and
the increase of +10°C of the S.A.R.A function.
After the second cycle the temperature value should be kept at the set
value +10°C until the request of the ambient thermostat is met.
Reduced Condensation Formation function
Positioning the adjusting DHW and CH temperature selector to the
"FCR" (reduced condensation formation, fi g. 33) zone, the highest de-
livery temperatures will be selected.
4.3 Switching off
Temporary switch-off
In the event of short periods of absence, set the function selector to
(OFF) (fi g. 34). The display will switch off.
In this way (leaving the electricity and fuel supplies enabled), the boiler
is protected by the following systems:
- Heating anti-freeze: this function is activated if the temperature
measured by the delivery probe drops below 5°C. In this phase, the
circulator is activated. If the boiler is not in lockout, the burner is also
activated at minimum output until the delivery water temperature
reaches 35°C. During the anti-freeze cycle, the symbol
appears on the digital display.
- DHW anti-freeze: the function is activated if the temperature
measured by the domestic water probe drops below 5°C. In this
phase, the circulator is activated. If the boiler is not in lockout, the
burner is also activated at minimum output until the delivery water
temperature reaches 55°C.
During the anti-freeze cycle, the symbol
display (fig. 35).
- Circulator anti-blocking: an operation cycle is activated every 24
hours after the last heat request.
Switching off for long periods
In the event of lengthy periods of absence, set the function selector to
(OFF) (fi g. 34). The display will switch off.
Turn the main system switch OFF.
Turn off the fuel and water taps of the heating and domestic hot water
system. In this case, anti-freeze device is deactivated: empty the sys-
tems, in case of risk of frost.
4.4 Operating status and faults
The operating status of the boiler is shown on the digital display, below
is a list of the types of displays.
Boiler status
Stand-by
OFF status
ACF alarm lockout module
ACF electronics fault alarm
Limit thermostat alarm
Air pressure switch alarm
Water pressure switch alarm
Anti-overfl ow pressure switch
alarm
Reed sensor (if the "Condense
neutralizer tray" kit is installed)
NTC domestic water fault
NTC heating fault
Parasite fl ame
Temporary, pending ignition
Air pressure switch intervention
Water pressure switch
intervention
Calibration
Preheating active function
Preheating heat request
External probe presence
Domestic water heat request
Heat request for heating
Antifreeze heat request
Flame present
Reset function
To restore operation (reset alarms):
(fig. 35)
appears on the digital
Display
Type of alarm
-
Signal
OFF
None
Defi nitive lockout
A01
Defi nitive lockout
A02
Defi nitive lockout
A03
Defi nitive lockout
A04
Signal
A06
Temporary stop
A07
Temporary stop
A11
80°C fl ashing
Temporary stop
Temporary stop
fl ashing
Temporary stop
fl ashing
Signal
ADJ
Signal
Signal
fl ashing
Signal
Signal
60°C
Signal
80°C
Signal
Signal

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mynute sinthesic 29 c.s.i.Mynute sinthesi 29 c.s.i

Tabla de contenido