Positioning
CLEARANCES REQUIRED
WHEN FITTING THE HOB WITH
A COOKER HOOD ABOVE
700mm
400mm
This appliance is to be built into a kitchen unit or 600mm worktop,
providing the following minimum distances are allowed;
The edges of the hob must be a minimum distance of 60 mm from a
side or rear wall.
700 mm between the highest point of the hob surface (including the
burners) and the underside of any horizontal surface directly above it.
400 mm between the hob surfaces, providing that the underside
of the horizontal surface is in line with the outer edge of the hob. If the
underside of the horizontal surface is lower than 400 mm, then it must
be at least 50 mm away from the outer edges of the hob.
50 mm clearance around the appliance and between the hob surface
and any combustible materials.
You must have a gap of at least 25 mm and at most 74 mm
between the underneath of the appliance and any surface that is below
it.
- An oven must have forced ventilation to install a hob above it.
- Check the dimensions of the oven in the installation manual.
- The cut out size must obey the indication.
CLEARANCES REQUIRED WHEN
FITTING THE HOB WITHOUT A
700m
m
400mm
16
COOKER HOOD ABOVE
400m
m
45 mm
400m
m
V.4