WSM KNG1600 Manual De Taller página 157

Tabla de contenido

Publicidad

S.5 ELECTRICAL SYSTEM / SISTEMA ELÉCTRICO
0120P118
Water Level Meter
1. Check that the pointer of the water level meter indicates LOW
level by the contact adjusting bolt when coolant in the crankcase
is empty.
2. If not, adjust with contact adjusting bolt.
3. Disconnect the water level meter lead.
4. Check the conduction with an ohmmeter across the water level
meter lead and chassis.
5. If not conduction when the pointer touches the contact of the
contact adjusting bolt, the water level meter is faulty.
If conduction when the pointer detaches from the contact of the
contact adjusting bolt, the water level meter is faulty.
Resistance
Factory spec.
Medidor de Agua
1- Controlar que la aguja o indicador del medidor del nivel de
agua indica LOW (Bajo) por contacto con el tornillo de ajuste,
cuando el refrigerante en el block está vacío.
2- De lo contrario, ajustar con el tornillo de ajuste de contacto.
3- Desconectar el cable conductor del medidor de nivel de agua.
4- Controlar con un ohmetro la conducción entre el conductor del
medidor del nivel de agua y el chasis.
5- Si no hay conducción cuando la aguja toca el contacto del
tornillo de ajuste de contacto, el medidor de nivel de agua es
defectuoso.
Si hay conducción cuando el indicador se separa del contacto del
tornillo de ajuste del contacto, el medidor del nivel de agua tiene
problemas.
Resistencia
Según fábrica
S-117
KNG 1600-3200(E) WSM,60184-0
When pointer touches contact
of contact adjusting bolt
When pointer detaches from
contact of contact adjusting bolt
Cuando la aguja toca
el contacto
Cuando la aguja se separa
del contacto
Conduction
∞Ω
Conducción
∞Ω

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kng1600eKng3200Kng3200e

Tabla de contenido