Parameter
Parameter name
code
Clock Timer
P34
repetition is valid
Cooling setting
P37
temperature
under auto mode
Heating setting
P38
temperature
under auto mode
Set priority
P43
operation
Clear Filter Clean
P46
accumulated time
Opening angle of
P49
indoor unit
air-return plate*
Parameter
range
00: once
01: repeat everyday
17°C~30°C(63°F~86°
F)
16°C~29°C(61°F~84°
F)
00: normal operation
01: priority operation
00: do not clear
01: clear
01: angle 1(25°)
02: angle 2(30°)
03: angle 3(35°)
29
Wired Controller XK46
Default
Note
value
Available only when timer is
00
set to clock timer.
25°C
When the temperature unit
(77°F)
is°C, cooling setting
temperature minus heating
setting temperature≥1°C.
When the temperature unit
20°C
is°F, cooling setting
(68°F)
temperature minus heating
setting temperature≥2°F.
When power supply is
insufficient, the indoor units
which are set to priority
00
operation can operate, while
other indoor units are forced
to be turned off.
00
Only applicable to units with
01
air-return plate
--