4.1 Electrical connection
The dishwasher's electrical connection and that of eventual supplementary apparatus is to be
entrusted to authorized and qualified personnel, with respect to the norms in vigor; observe also the
technical regulations for the connections.
The total power installed is given upon the apparatus' technical data label.
Other apparatus must not be protected along with the dishwasher.
The user must provide for the installation, according to the norms in vigor, of a main electrical power
switch and of a differential switch compatible with the machine's characteristics.
These switches must be installed near the dishwasher, be easily accessible after installation and
guarantee complete disconnection from the electrical supply in category III overvoltage conditions.
Caution!!!
The dishwasher is free of electrical current only when the main switch is off.
-
Connect the apparatus to the usage equalizer. The
back of the machine.
-
The protection conductor (PE) is yellow-green in color, the neutral conductor (N) is blue and the
phase conductors (L1, L2, L3) are black, gray and brown.
FIRST STARTUP
The electrical protection system must be subjected to a functional test before use. The installation must be
performed and/or verified by the authorized reseller who will be responsible for the first startup and the
instructions relative to the dishwasher's operation.
PREPARATION FOR USE
Important:
The rinse-aid metering unit comes equipped in all models
while the detergent metering unit comes equipped in only
some models.
If both metering units are present position the external
detergent and rinse-aid containers and insert their
respective suction tubes located at the back of the machine.
Red tube: detergent
Transparent tube: rinse-aid
Before inserting the tubes in the containers apply the weight
(necessary to keep the tube at the bottom of the container)
and the filter as indicated in the diagram.
For adjustments, use the adjustment screws indicated in the diagram. It is
recommended that adjustments be performed by personnel from the companies who
have supplied the detergent products.
If the detergent metering unit did not come pre-installed it can be installed at a later
time by ordering the relative KIT.
Alternatively, an external metering unit can be connected by means of an electrical
connection with a 2x0.5 mm type H05 RN-F cable. This cable must be inserted through
the passage indicated in the TECHNICAL CHARACTERISTICS scheme and
connected in accordance with the electrical scheme furnished with the dishwasher.
The metering unit must be of 230V/50Hz with a maximum absorbed power of 15W.
Connect the detergent metering unit to the dishwasher through the red tube cited above.
.
5 FIRST STARTUP
clamp for the connection is located at the lower
6