PARAMETER
VALUE
r L
1
2
3
4
Fun
Mon
biS
t iM
1" - 7'30"
tEL
0 - 1007
CLt
no
Si
rLC
no
Si
End
no
Si
DESCRIPTION
RELAY OUTPUT SELECTION
It enables the user to select one of the four relay outputs available: the
transmitters that are about to be saved subsequently will be associated to the
relay selected
Relay output 1
Relay output 2
Relay output 3
Relay output 4
FUNCTIONS : It enables the user to select one of the following functions
MONOSTABILE : it activates the corresponding relay through the time of
access device transmission. When the transmission stops, the relay goes
automatically off.
BISTABILE : it activates the corresponding relay on the first access device
transmission. The relay goes off on the second transmission
TIMER : Access device transmission activates the corresponding relay that is
disabled automatically after a time that can be set from 1.0" to 7'30 with the
following intermediary steps: 1.0" - 2.0" - 3.0" - 4.0" - 5.0" - 6.0" - 7.0"
- 8.0" - 9.0" - 10.0" - 11.0" - 12.0" - 13.0" - 14.0" - 15.0" - 30.0" - 1'00 -
1'30 - 2'00 - 2'30 - 3'00 - 3'30 - 4'00 - 4'30 - 5'00 - 5'30 - 6'00 - 6'30 - 7'00
- 7'30
ACCESS DEVICES (save and delete)
To memorize the access devices proceed as follows:
1. When on display is shown
on display is shown the memory cell
NOTE: the occupied memory cells are displayed discontinuously
2. Should you intend to save the new access device into a specific memory
cell, select the desired cell and proceed. If no specific cell was selected, the
access device is memorized in the first cell available.
3. Send data with the access device that you intend to save in the memory:
the memory cell in which the new access device was saved is flashing on
display
4. Send data with the other access devices to be memorized:
the occupied memory cell is flashing on display
To delete the access device saved in the memory, proceed as follows:
1. Select the memory cell to be deleted: the cell is flashing on display
2. Hold the MENU key pressed until the cell is displayed steadily
DELETE ALL
This menu enables deleting all access device saved in the memory
Deletion is not completed
Deletion in progress: on display is shown
completed
ROLLING CODE mode
WARNING: if VRD / PROKSIMA is used as a control device, the rolling code
mode has always to be not activated
ROLLING CODE mode disabled
ROLLING CODE mode enabled
Exit the programming menu
Do not exit the programming menu
Exits the programming menu by storing the parameters set
t EL
press the MENU key:
0000
CLr
until the operation is
- 7 -
DEFAULT
MEMO
1
Mon
no
no
no