Floor Mount
Wall Mount
Ceiling Mount
2. Installing the Fan Coil
Wine Guardian split system fan coil units should be
installed indoors located near the wine room. Provide a
three-foot clearance around the unit for installation and
future maintenance. The fan coil unit can be located
either above, or below the condensing unit in height.
Keep any height difference to a maximum of
15' (4.57meters).
Floor Mounting
•
Mount the Wine Guardian fan coil on a plywood
surface at least 12 inches above the floor to keep it
away from water. Allow adequate space for the
routing and pitch of the external drain.
Wall Mounting
•
Provide adequate support on both ends of the unit
to accommodate the weight of the system. Construct
a structurally sound level platform, supported by
angle brackets fastened to the wall.
Ceiling Mounting
•
Construct a structurally sound, level platform to
place the unit on when hanging it from the ceiling
joists. The system is NOT designed to be suspended
from the top of the unit; it must be supported from
the bottom.
3. Installing Thermostat (Wired)
A.
Unit is supplied with 50 feet (15 meters) of cable with
RJ-9 type connection along with the Remote User
Interface Controller.
B.
Locate the Remote User Interface within the room
midpoint on a wall in an area with good airflow and
away from any windows or heat sources.
C. Disconnect the wire from the back of the controller and
route the cable to the desired mounting location within
the room.
D. Provide a 3/4" (19 mm) diameter hole within the wall or
racking structure to provide clearance for routing of the
RJ-9 connection at the back of the controller.
E.
Remove the back plate of controller and mark
mounting points at the desired location.
F.
Drill two 1/8" (3 mm) holes and insert anchors within
mounting surface. Anchors may not be required if
securing to wall studs or racking. Insert screws into the
anchors and test fit the installation of the backing plate.
Tighten/loosen screws to create a snug fit.
4