Motor Power; Start Off; Start In Opening; Start In Closing - V2 PD5 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

MOTOR POWER

This menu permits to adjust the motor power from
30 to 100% with a scanning of ±0,5.

START OFF

When the gate is at a standstill and is going to
move, it is contrasted by the starting inertia. As a
consequence of this, if the gate is very heavy the
gates might not move. By activating the start off
function, it is possible to win the initial inertia thanks
to the motor start to the maximum of the power for
2 seconds.

START IN OPENING

This menu permits to select the functions of start
during the opening phase.
PAUS
the command START stop the gate and
goes into in PAUSE.
no
the command START is not available.
ChiU
the command START close the gate.

START IN CLOSING

This menu permits to select the functions of start
during the closing phase.
StoP
the command START stop the gate.
APEr
the command START open the gate