I
MPORTANT FOR THE USER
- The device can be used by children aged 8 years and above and persons with reduced physical ,sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe wayand understand the hazards involved.
- these instructions are also available at the website
- Do not allow children to play with the device and keep the radio-controls away from their reach.
- Frequently examine the system to detect any signs of damage. Do not use the device if it is in need of repair
work.
- Always remember to disconnect the power supply before carrying out any cleaning or maintenance.
- Cleaning and user maintenance shall not be made by children without supervision.
WARNING: Important Safe Instructions.Follow all instructions since incorrect installation can lead to severe injury.
FOR THE INSTALLER – IMPORTANT:
− Before gate automation, it is necessary to check the good condition of the gate and its compliance with
EN 12604 with respect to directive on machines.
− Check that the location where the installation is located enables compliance with operating temperature limits
specified for the device.
− The safety of the final installation and compliance with all prescribed Standards (EN 12453 - EN 12445) is the
responsibility of the person who assembles the various parts to construct a total closing.
− Once installation is finished, it is recommended that all necessary checks be performed to ensure that
compliant installation has been performed.
− The control unit is not equipped with 230 Vac electric line sectioning device. The installer is responsible for
installing a sectioning device in the system. The sectioning device must be protected against accidental
closing in compliance with 5.2.9 section of EN 12453.
−
For the power supply cables, use flexible cables in an insulating sheath in harmonised polychloroprene
(H05RN-F) with a minimum conductor section of 1mm2
− The various electrical components external to the control unit must be cabled in accordance with standard EN
60204-1 as amended, and as set forth in point 5.2.7 of EN 12453. The power supply cables can have a maximum
diameter of 14 mm; the power supply and connecting cables must be set up through the assembly of cable
glands, supplied as "optional".Pay careful attention when fastening the cables so that they are stably anchored in
a stable manner. Furthermore, care is required when drilling holes in the outside casing where connecting and
power supply cables will pass, and when assembling the cable glands, so that everything is installed so as to
maintain the panel's IP protection characteristics.
− The possible assembly of a keyboard for manual control must be done positioning the keyboard so that the
user is not placed in a dangerous position.
− The rear part of the casing is equipped with fittings for wall mounting (it is possible to drill holes for installation
with plugs, or there are already holes available for installation with screws). Plan and implement all necessary
measures to achieve an installation that does not alter the IP protection.
− The motor reducer used to move the automation must comply with section 5.2.7. of EN 12453.
complies with requirements of Directives EMC 2014/30/EU, LVD 2014/35/EU.
LG 2279
www.seav.com
Electronic Control Unit LG 2279
(GB)
TECHNICAL INSTRUCTIONS