ERROR CODE
3100
3101
3102
3103
3104
3105
7600
7603
7800
7802
9000
2F01
NOTICE: IF ERROR CODE/FAULT OCCURS TURN KEY SWITCH OFF AND THEN BACK ON.
For further codes and explanations, contact a Clarke Service Center.
Clarke
®
Operator's Manual (EN) - FOCUS S28/L28/S33/L33/S38/L38 WB
CAUSE
Probable short circuit of output device.
Open circuit on brush motors
or brush motor wiring.
Possible short circuit on
brush motors or wiring.
Open circuit on traction motor.
Traction motor current has exceeded
current limit for the fold back time.
Brushes not fi tted.
Drive system activated prior to turning key
switch "ON".
ENGLISH
ACTION
Check the traction, brush and vac motor
connections on the trio and check wiring
from these connectors down to the traction,
brush and vac motors.
Check the brush motor connection on the
trio and check the wiring from this
connector down to the brush motor.
Check the traction motor connection on
trio and wiring down to motor.
Excessive driving up an incline, or machine
driven up against an obstacle or step.
Brushes
Release traverse switch and reactivate.