8� Warranty
As purchaser, you are entitled to your statutory rights against the vendor.
If these rights exist in your country, they are neither curtailed nor restricted by
our Warranty Declaration. We guarantee that your STEINEL Professional sensor
product will remain in perfect condition and proper working order for a period
of 5 years. We guarantee that this product is free from material-, manufactur-
ing- and design flaws. In addition, we guarantee that all electronic components
and cables function in the proper manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your product complete and carriage
paid with the original receipt of purchase, which must show the date of
purchase and product designation, either to your retailer or contact us at
STEINEL (UK) Limited, 25 Manasty Road, Axis Park, Orton Southgate,
Peterborough, PE2 6UP, for a returns number. For this reason, we recom-
mend that you keep your receipt of purchase in a safe place until the warranty
period expires. STEINEL shall assume no liability for the costs or risks involved
in returning a product.
For information on making claims under the terms of the warranty, please go to
www�steinel-professional�de/garantie
If you have a warranty claim or would like to ask any question regarding your
product, you are welcome to call us at any time on our Service Hotline
01733 366700.
5
Y E A R
MANUFACTURER'S
WARRANTY
- 24 -
9� Technical specifications
Dimensions W x H × D
Supply voltage
Sensor system
Reach
Angle of coverage
Capacity, switching output 1
Minimum connected load
Light-level setting
Time setting
Mounting height (minimum)
IP rating
Temperature range
10� Troubleshooting
Malfunction
Cause
Light does not switch ON n No supply voltage
n Lux setting too low
n No motion being
detected
Sensor responds
n State of charge not
when it should not
sufficient
80 × 80 × 50 mm
220-240 ~V / 50/60 Hz
Passive infrared (IR)
max. 20 m (tangential) / max. 4 m (radial)
180°
Relay 230 V
max. 200 W resistive load (cos φ = 1)
max. 6 fluorescent lamps /
LED lamps C < 132 µF
max. 100 VA (cos φ = 0.5)
3.5 W
2-1000 lux, ∞ / daylight
30 s - 15 min
1.1 m
IP20
0°C to + 40°C
Remedy
n Check supply voltage
n Slowly increase lux set-
ting until light switches
ON
n Ensure unobstructed
sensor vision
n Check detection zone
n With a very low state
of charge, lighting is
switched ON irrespec-
tive of movement, see
SuperCap charging
behaviour
- 25 -