Do not use means to
accelerate the defrosting
process or to clean, other than
those recommended by the
manufacturer.
The appliance shall be stored
in a room without continuously
operating ignition sources
(for example: open flames, an
operating gas appliance or an
operating electric heater.
Do not piece or burn.
Be aware that refrigerants
may not contain an odour.
Appliance shall be installed,
operated and stored in a
room with a floor area larger
than Xm2, where X is the
"minimum area" shown in
section 3.2 and section 8.0.
1005494 ISSUE 6
The heat pump must be kept
away from sources of fire or
naked flames.
The heat pump must be
installed in well ventilated
area. Closed areas are not
permitted.
Repair and disposal must
be carried out by F-Gas
registered engineers.
Completely de-gas the
refrigerant before any brazing
is performed. Brazing can only
be carried out by technicians
trained to EU 517/2014.