UNPACK

Verify integrity of the pack at the moment of the reception of the apparatus. Verify on the
back side the yellow adhesive nameplate QUALITY CONTROL PASSED the control code
is integral. Verify that in the packaging all the parts and the supplied accessories of series
are contained together with the apparatus: power cord, suction hose and connection, pack
of 4 filters, user's documentation and warranty.

INSTALLATION

Take the suction unit out of the packaging and place it where can be easily inspected for
the replacement of the recovery filter of powders (rif.14) and for the periodic substitution of
the filter for motor protection (rif. 12 - cod. 3106012). ATTENTION: do not place the
apparatus inside a piece of furniture without circulation of air.
Open the lateral panel (rif. 33) rotating the two screws (rif. 32).
Insert the suction hose making a light pressure (rif. 5) in the appropriate metal ring (rif. 11).
Make sure of the proper placement of the recovery filter of powders (rif. 14) in the
appropriate plexiglass connection of the suction hose (rif. 5), then close the lateral panel
(rif. 33).
Connect the power cord (rif. 1) in the plug of the unit (rif. 27) and the other head of the
cord to a power outlet (absorption max 800 W). ATTENTION: make sure that the voltage
corresponds to the one brought back on the fabrication nameplate placed on the
apparatus.
Connect the other side of the suction hose (rif. 5) where you need to have the aspiration:
(rif. 6/7/8/9/35 - cod. 110), benches, sandblasters, dry trimmers (for the use of the suction
unit with a dry trimmer it is recommended to connect it to a decantation box for dry
powders type).
After these operations, the suction unit is now ready to work: turn on the apparatus by
pressing the general switch (rif. 28) and regulate the aspiration power acting on the power
regulator (rif. the 29) min 400 W - max 800 W.
ATTENTION: the filter (rif. 14) has a very important function for the
perfect operating of the apparatus and for your health. Check it
periodically and replace it before it is completely full. Do not use the
same filter more than one time, and do not discharge it. Non-
observance will void your warranty. Once exausted the filter close it
with a proper adhesive tape and waste appropriately in compliance with
your country rules.