MAINTENANCE
Substitution of the used filter of powders:
Open the lateral panel (rif. 33) of the suction unit removing the two screws (rif. 32), control
the bag of used powders every 4/5 days and replace it before completely full (max to
approximately 2/3 of its capacity). Place a new filter bag making a light pressure upwards
untill it is perfectly fitted in the plexiglass connection (rif. 5). Do not re-use and do not
empty out the used filters. When the filter is exausted close it with a proper adhesive tape
and waste appropiately in compliance with your country rules.
Substitution of the motor protection filter:
Remove the metal central panel screw (rif. 30), rotating the metal holder disk (rif. 31); pull
and extract upwards the filter. Insert a new filter (rif. 12 - cod. 3106012) and close the all
making operations to the contrary. Check every two weeks the motor protection filter and
clean it by blowing compressed air in the same way of passage of the sucked air. The filter
must be replaced with a new one at least every 4 months. This preserves the motor and
the perfect operating of the apparatus.
GUIDE TO COMMON QUESTIONS
The apparatus is not turning on:
1. Control that the power cord plug (rif. 1) is properly connected to the electrical outlet.
2. Check that fuses (rif. 24) are not damaged.
The suction power is low:
1. Replace the recovery dust filter (rif. 14), and/or replace the motor protection filter (rif.
12).
2. Check that the motor is correctly placed in the center of its site (rif. 17a23).
Carried out these controls, in case the apparatus still presents disadvantages, contact the
customers' technical service.
SPECIFICATIONS
Fuses: 2 from 5 x 20 mm. 6.3 Ampere - cod. 3106024 Power max 800 Watt.
Operating voltage V/Hz 230/50-60 (see nameplate on the apparatus)
Weight Kg. 11
DIMENSIONS
Height cm. 40 Width cm. 33 Depth cm. 25