Pump LED diagnose and remedy
The pump have an LED operating status display, this makes it easy
for the technician to search for the cause of a fault in the heating
system.
1. If the LED display lights up continuously green, it means the pump
is running normally.
2. If the LED display is flashing green, it means the pump is running
venting routine. The pump runs during 10min in venting function,
afterwards the installer has to adjust the targeted performance.
3. If the LED is flashing green/red, it means the pump has stopped
operating due to an external reason. The pump will restart by itself
after the abnormal situation disappeared. The probably reason to
cause the problem is that the pump undervoltage or overvoltage
(U<160V or U>280V), you should check the voltage supply. Another
reason is the module overheating, and then you should check the
water and ambient temperature.
4. If the LED is flashing red, it means the pump has stopped
operating, some serious fault has happened(e.g. pump blocked), the
pump cannot restart itself due to a permanent failure and the pump
should be changed.
5. If the LED is not light up, it means no power supply to the pump,
maybe the pump is not connected to power supply, you should check
the cable connection. If the pump is still running, it means the LED is
damaged. Or the electronics are damaged and the pump should be
changed.
Failure diagnosis at the moment of first installation
■ In case nothing is displayed on the user interface, check for any
of the following abnormalities before you can diagnose possible
malfunction codes.
1) Disconnection or wiring error (between power supply and unit
and between unit and user interface).
2) The fuse on the PCB may have run out.
■ If the user interface shows "E8"or"E0" as an error code, there is a
possibility that air exist in the system, or the water volume in the
system is less than the minimum volume.
■ If the error code "E2" is displayed on the user interface, check for
the wiring between user interface and unit.
More error code and failure cause can be found in "Error codes".

6.7 Field settings

The unit shall be configured by the installer to match the installation
environment (outdoor climate, installed options, etc.) and user
demand. Thereto, a number of so called field settings are available.
These field settings are accessible and programmable through the
"FOR SERVICEMAN" in user interface.
Procedure
To change one or more field settings, proceed as follows.
Temperature values displayed on the digital controller (user
interface) are in °C
Keys
Function
MENU
• Go to the menu structure (on the home page)
• Navigate the cursor on the display
◄► ▼ ▲
• Navigate in the menu structure
• Adjust settings
• Turn on or off the space heating/cooling operation
ON/OFF
mode or DHW mode
• Turn on or off the function in the menu structure
BACK
• Come back to the up level
• Long press for unlock /lock the controller
UNLOCK
• Unlock /lock some function such as "DHW
temperature adjusting "
• Go to the next step when you are programming a
OK
schedule in the menu structure confirms a
selection enter a submenu in the menu structure
About FOR SERVICEMAN
"FOR SERVICEMAN" is set up for installer when using to set the
parameter.
1. Setting the composition of equipment.
2. Setting the parameter.
How to go to FOR SERVICEMAN
Go to MENU> FOR SERVICEMAN. Press OK
FOR SERVICEMAN
Please input the password:
0
ENTER
ADJUST
OK
The password is 666. Use ◄、► to navigate and use ▼、▲ to
adjust the numerical value. Press OK, then the following page will
appear:
FOR SERVICEMAN
1. DHW MODE SETTING
2. COOL MODE SETTING
3. HEAT MODE SETTING
4. AUTO MODE SETTING
5. TEMP.TYPE SETTING
6. ROOM THERMOSTAT
7. OTHER HEATING SOURCE
ENTER
SCROLL
OK
Use ▼、▲ to scroll and use "ok" to enter submenu for setting the
parameters.
6.8 DHW control
■ About DHW mode
DHW:domestic hot water
DHW MODE SETTING typically consists of the following :
1. DHW MODE: enable or disable the DHW mode
2. TANK HEATER: set whether the booster heater available or not
3. DISINFECT:set the parameters for disinfection
4. DHW PRIORITY:set the priority between domestic hot water
heating and space operation
5 DHW PUMP:set the parameters for DHW pump operation
The above functions applies only to installations with a domestic hot
water tank.
■ How to set the DHW mode
To determine whether the DHW mode is effective.
Go to MENU> FOR SERVICEMAN> DHW MODE SETTING .Press
OK. The following page will appear.
32
0 0
SCROLL
FOR SERVICEMAN
8. HOLIDAY AWAY MODE SETTING
9. ECO/COMFORT MODE SETTING
10. SERVICE CALL SETTING
11. INITALIZE MANUALLY
12. TEST RUN
13. SPECIAL FUNCTION
14. AUTO RESTART
ENTER
SCROLL
OK
V.1