1.800.544.2843
Operating the Battery Sonde with a Push Cable
To install the NaviTrack Battery Sonde trans-
mitter onto a push cable, screw the threaded
end of the battery cover onto the end of the
push cable. Tighten with pliers to ensure sure it
does not disconnect or loosen during use.
NaviTrack Battery Sonde Specifications
Weight:
with AAA alkaline battery
Size:
Length
Width
Typical Maximum Detection Range*:
In air
In cast iron
Operating Frequency
Frequency Tolerance
Current Draw Tolerance
Mounting Threads
Battery:
Battery type
Recommended battery type
Operating temperature
Expected life with recommended
battery type
Typical Interference sources
*
Will vary with ambient noise and interference
www.calcert.com
15
10
20
5
25
0
30
NaviTrack
Battery Sonde
®
0.9375 in [2.38 cm]
± 30 – 50 ppm (0.00005 Hz)
Duracell MX 2,400 AAA cells
3.5 hours at 70°F [21°C]
ductile iron, cast iron, wet salt
3.5 oz [100 g]
2.92 in [7.42 cm]
25 ft [7.6 m]
15 ft [4.6 m]
512 Hz
± 0.015A
¼" – 20
one AAA alkaline
(M3 Ultra)
–4°F to 130°F
[–20°C to 54°C]
laden ground
English - 3
sales@calcert.com