Troubleshooting

Symptom
Possible Cause(s)
Disconnect switch is off
Fuse is blown or circuit breaker tripped
Starting switch is defective
Motor will not run
Wires at motor are loose, disconnected, or
wired incorrectly
Pressure switch contacts are dirty
Motor is wired incorrectly
Motor runs hot and overload
Voltage is too low
kicks off
Pump cycles too frequently
Pump in new installation did not pick up
prime through:
1. Improper priming
2. Air leaks
3. Leaking foot valve or check valve
Pump has lost prime through:
1. Air leaks
2. Water level below suction pipe inlet
Motor runs but no water is
delivered*
Foot valve or strainer is plugged
Ejector or impeller is plugged
Check valve or foot valve is stuck shut
* Stop pump; then check
Pipes are frozen
prime before looking for
other causes. Unscrew
Foot valve and/or strainer are buried in
priming plug and see if
sand or mud
water is in priming hole.
Water level is too low for shallow well
setup to deliver water
Water level in well is lower than estimated
Pump does not deliver water to
Steel piping (if used) is corroded or limed,
full capacity (Also check point 3
causing excess friction
immediately above)
Piping is too small in size
Pressure switch is out of adjustment or
contacts are welded together
Faucets have been left open
Venturi, nozzle or impeller is clogged
Standard pressure tank is waterlogged and
has no air cushion
Pump delivers water but does
Pipes leak
not shut off or pump cycles too
frequently
Foot valve leaks
Pressure switch is out of adjustment
Air charge too low in pre-charged tank
Pump is picking up prime
Leak in suction side of pump
Air spurts from faucets
Well is gaseous
Intermittent over-pumping of well. (Water
drawn down below foot valve.)
Corrective Action
Be sure switch is on.
Replace fuse or reset circuit breaker.
DISCONNECT POWER; Replace starting switch.
Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and
tighten all wiring.
Risk of electric shock . Can shock, burn or kill. Capacitor
voltage may be hazardous. To discharge capacitor, hold insulated handle
screwdriver BY THE HANDLE and short capacitor terminals together. Do not
touch metal screwdriver blade or capacitor terminals. If in doubt, consult a
qualified electrician.
DISCONNECT POWER and file contacts with emery board or nail file.
Refer to instructions on wiring.
Check with power company. Install heavier wiring if wire size is too small (See
Electrical / Wiring Chart).
See section below on too frequent cycling.
In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line, AVC, and ejector with soapy water or
shaving cream.
3. Replace foot valve or check valve.
In installation already in use:
1. Check all connections on suction line and shaft seal.
2. Lower suction line into water and re-prime. If receding water level in well
exceeds 25' (7.6M), a deep well pump is needed.
Clean foot valve or strainer.
Clean ejector or impeller.
Replace check valve or foot valve.
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source. Clean foot valve
and strainer.
A deep well jet will be needed if your well is more than 25' (7.6M) depth to
water.
A new nozzle and venturi combination may be needed.
Replace with plastic pipe where possible, otherwise with new steel pipe.
Use larger piping.
DISCONNECT POWER; adjust or replace pressure switch.
Close faucets.
Clean venturi, nozzle or impeller.
Drain tank to air volume control port. Check AVC for defects. Check all
connections for air leaks.
Check connections.
Replace foot valve.
Adjust or replace pressure switch.
DISCONNECT POWER and open faucets until all pressure is relieved. Using
tire pressure gauge, check air pressure in tank at valve stem located on the tank.
If less than pressure switch cut-in setting (30-50 PSI), pump air into tank from
outside source until air pressure is 2 PSI less than cut-in setting of switch. Check
air valve for leaks (use soapy solution) and replace core if necessary.
When pump has picked up prime, it should pump solid water with no air.
Suction pipe is sucking air. Check joints for leaks with soapy water.
Consult factory about installing a sleeve in the well.
Lower foot valve if possible, otherwise restrict pump discharge.
11