Trouble shooting

Symptom
Counter measures
Red LED indicator light is on
and the tool does not operate.
Tool operates normally but
does not drive the fasteners
to flush.
Fan does not run, and the LED
indicator light is red.
Battery is unable to charge, or
the battery charger is getting
hotter when charging.
Battery charger is getting
hotter, produces noise or start
to smoke.
Work contact element (safety)
is not fully depressed and the
tool cannot be used.
Tool does not operate, but the
Green LED indicator light is on
and the fan can work.
Tool operate normally, but no
fastener is driven.
Combustion chamber is not
returning to start position.
Driver did not return to initial
position, miss fire frequency
get higher than usual.
Battery power might be too low.
Replace battery with a fully charged
one.
Adjust the depth of drive setting to
deepest.
Clean the cylinder with proper
cleaner.
Check battery and replace as
required.
Depress the safety and hold for 1
minute before activating the trigger.
If the tool does not fire, there might
be seal leaking over the combustion
chamber. Send to service center
near you.
The battery is dead. Replace the
battery with a fully charged one.
If all above-mentioned conditions
do not work, send to service center
near you.
Replace the battery. If this action
solves the problem, the battery is
damaged or exhausted.
Replace the battery charger if the
battery is functioning normally on
tool but cannot be charged by the
battery charger.
The battery charger is damaged and
should not be used any more. Unplug
the battery charger immediately and
replace it with a new battery charger.
The work contact element is bending,
or some dirt is stuck in the track of
the safety mechanism. Clean the sa-
fety track. Repair or replace the work
contact element by service center
representative.
Lock out mechanism is active. Load
more fasteners.
Run out of fuel, replace a new fuel
cell.
Spark wire is loose, check the spark
wire by removing the cap.
Spark plug is dirty. Clean the spark
plug.
If all above-mentioned conditions
do not work, send to service center
near you.
Wrong type of fasteners is used.
Please change to correct fasteners.
The cylinder needs cleaning.
Fastener is jammed, clean the jam-
med fastener before use.
The fastener pusher did not engage
properly with the fastener strip.
Adjust to fully engagement.
The work contact element (safety)
is bending or dirty. Check the work
contact element and repair or replace
it. Clean the safety track.
Check and replace full battery.
Clean the tool with proper cleaning
fluid.
Check for piston ring wear status.
The tool maybe over heated. Clean or
replace the
intake air filter.
Tool appears to be losing
power.
For failure other than above situation, please stop using the tool and contact
your local dealer for service.
Please send the tool back to the tool manufacturer/distributor if failure other
than those as tabulated above occurs.
English
Check fuel cell.
Clean or replace air intake filter.
Check spark plug wire.
Clean the tool with proper cleaning
fluid.