6. Manual Start of Egg Tray Rotator Operation with Engine Button
7. Self Tune Metod
Self Tune method is used for determining PID parameters used by the device.
Starting Self Tune (Step Response Tuning) Operation by the user :
• Adjust t
emperature control on/off or PID parameter
(
=1)
• Adjust self tune selection parameter (
• In the main screen "Tune" and Temperature value are should alternately.
If Self Tune operation is finished without any problem, the device saves the new PID coefficients to
memory and continue to run.
NOT: The temperature value read from the sensor must be less than 5% of the process set value in order
to start the self tune operation (5 ° C for the ProNem Mini PMI-P sensor).
Cancelling Self Tune(Step Response Tuning) operation :
1 - If sensor breaks;
2 - If auto tune operation can not be completed in 8 hours ;
3 - If user adjusts
4- During self tune operation if the user changes the temperature control from pid to on/off;
5 - If process set value is changed while self tune operation is being performed;
Self tune is canceled. "Tune" is not displayed. Then, without doing any changes in PID parameters,
device continues to run with previous PID parameters.
8. Specifications
Device Type
Housing&Mounting
Protection Clas
Weight
Enviromental Ratings
Storage / Operating Temperature
Storage / Operating Humidity
Installation
Overvoltage Category
Pollution Degree
Operating Conditions
Supply Voltage and Power
Temperature Sensor Input
While button protection parameter value is
4 in main operation screen if engine button is pressed,
3 sec.
manual engine start will be active.When the button is
released the engine start will be passive and engine stops.
ü
Parameter is adjusted
parameter
;
: Hatcher Controller
: 76 mm x 34.5 mm x71 mm Plastic housing for panel
Panel cut out is 71 x 29 mm.
: Ip65 at front, Ip20 at rear.
: Approximately 0.2 Kg
: Standart,indoor at an altitude of less than 2000 meters with
none condensing humidity.
o
: -30 C to +80 C / -20 C to +70 C
: 90 % max. (None condensing)
: Fixed installation
: II.
: II, office or workplace, none conductive pollution
: Continuous
:
230V
: 115
: 24
V
: 24
V
: 10 -30
: NTC, PTC, PT-100,0/2..10VZ,0/4..20mAZ or
ProNem Mini PMI-P
=
)
o
o
V ±
( %15) 50/60Hz - 1.5VA
V ±
V
( %15) 50/60Hz - 1.5VA
V ±
( %15) 50/60Hz - 1.5VA
W ±
( %15) 50/60Hz - 1.5VA
VZ 1.5W
automatically.
o
0,1,2 or
16