Technical Specifications - Tecnogas MagBlue Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Components
inlet valve
1
Filtered water outlet pipe
2
Locking ring nut
3
Stopper
4
Drain valve
5
Vent valve
6
Magnet housing
7
Mechanical filter
8
Filter hole
9
Removable magnet
10
90° bend for horizontal installation
11
ENGLISH

Technical specifications

Maximum work pressure
Water max. temp.
Environment min. temp.
Maximum hourly flow
Internal mount
1.
Unscrew the
ring
3
2.
To ensure correct function the
.
6
3.
In turn, closing the upper part of the magnetic dirt separator, the
aligned with the
drain valve
4.
Once properly positioned the components, it is necessary to fix again (without the use
of tools) the
ring nut
This procedure has already been performed on each magnetic dirt
!
separator. It is only necessary in the case of maintenance operations that
require access to the filter.
TECNOGAS manuale di installazione | setup manual
PN 4 bar
Magnetic flow density
90 °C
Body material
5° C
Fittings material
1,38 m3/h
Fittings diameter
and remove the upper part of the filter
filter hole
should be vertically aligned to the
9
.
5
.
3
12900 Gauss
Plastimid 66 Neutro
Ottone nichelato
3/4"
vent valve
vent valve
must be
6
11

Publicidad

Tabla de contenido
loading

Productos relacionados para Tecnogas MagBlue

Este manual también es adecuado para:

70048

Tabla de contenido