ENGLISH
Structure of Advanced soldering stations
system
The Advanced series has basic modules giving
you full flexibility for choosing what you need for
the work in hand, the modules being supplied
separately.
Dual control unit
- AD 4200 EU
- AD 4200 UK
Model AD 4200 can be used with two tools
simultaneous, either handpieces or desoldering
tweezers. Can be used with either combination of
2010, 2210, 2045 and 2245 handpieces and the hot
tweezers PA 1200 or PA4200.
Handpieces
- 2010
Power: 20W. For high precision work, SMD, etc.
- 2210
Power: 20W. For high precision work, SMD, etc.
- 2045
Power: 50W. For general soldering work.
- 2245
Power: 50W. For general soldering work.
Hot tweezers
- PA 1200
For general precision desoldering with SMD
components.
Power: 40W.
Effective power per cartridge fitted: 20W.
- PA 4200
For general desoldering and soldering work in
professional electronics.
Power: 100W.
Effective power per cartridge fitted: 50W.
Cartridges
- Range of cartridges 2010 (for the 2010 handpiece).
- Range of cartridges 2210 (for the 2210 handpiece).
- Range of cartridges 2045 (for the 2045 handpiece).
- Range of cartridges 2245 (for the 2245 handpiece).
- Range of cartridges for micro hot tweezers PA 1200.
- Range of cartridges for hot tweezers PA 4200.
Stands
- Soldering iron stand AD 8200
- PA 8420
Stand for the hot tweezers PA 4200.
- PA 8100
Stand for the hot tweezers PA 1200 and PA 4200.
For a dual soldering station work properly is
necessary: the dual control unit, a handpiece or the
hot tweezers, and the corresponding stand and
cartridge.
Dual control unit AD 4200
The station is supplied with:
- Control unit.
- Connection cable to mains.
- Instructions manual.
- Transport packaging.
Technical specifications
Ref. 4200200
- Temperature selection from 100 to 371°C (±5%).
Ref. 4200201
- Power: 135W.
- Safety transformer, mains separator and double
isolation, with integrated fuse of temperature
protection.
- Input: 230V 50Hz. Output: 24V.
- Electrical protection Class I.
- Total weight of unit: 5Kg.
- ESD protected housing.
Ref. 2010000
Typical surface resistance: 10
square.
Ref. 2210000
- Complies with CE standards on electrical safety,
electromagnetic compatibility and antistatic
protection.
Ref. 2045000
- Equipotential connector is earth connected to the
plug feed of the station.
Ref. 2245000
RECOMMENDATIONS FOR USE
Ref. 1200000
For soldering and desoldering
-
Clean the contacts and the printed circuit to
be desoldered of dust or dirt.
-
Preferably select a temperature below 350°C.
Excess temperature may cause the printed
Ref. 4200000
circuit tracks to break loose.
-
The tip must be well tinned for good heat
conduction. If it has been inoperative for any
length of time, it should be retinned.
Ref. 0268200
Ref. 0748420
Ref. 0748100
2
5
-10
11
Ohms/