Pinnacle Climate Remington REM-L180ALT-F Manual Del Usuario página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MANTEL CLEARANCES
In addition to meeting noncombustible material clearances, you must also meet required clearances between
the fireplace opening and mantel shelf. A fireplace hood is required if the below clearances are not met.
Determining Mantel Clearances:
If you meet the minimum clearance requirements between the mantel shelf and the top of the fireplace
opening, you do not require a fireplace hood (see Fig. 5).
Noncombustible
Material Distance
8" or more
Less than 8"
Determining Minimum Mantel Clearance When Using a Hood:
If the minimum clearances in Fig. 6 are not met, you must use a hood. When using a hood there are still
certain minimum mantel clearances required, as shown in Fig. 6.
Fig. 5—Closed Flue Mantel
Clearances without Hood
NOTICE: When operating the heater, the surface temperature of adjacent walls and mantels become hot. Walls
and mantels above the firebox may become too hot to touch. If installed properly, these temperatures meet
the requirement of the national product standard. Follow all minimum clearances shown in this manual.
NOTICE: If your installation does not meet the minimum clearances, you must only operate the heater with
the flue damper open, or you must raise the mantel to an adequate height.
©2017 Pinnacle Climate Technologies
Installation (cont.)
Noncombustible Material Installation Requirements
Noncombustible material is okay.
Noncombustible material must be extended to at least 8". See between 8" and
12" on the previous page. If you cannot extend the material, the heater must be
operated with the flue damper open.
Maximum
10"
Combustible
Mantel
Minimum 20"
Requirements for Safe Installation
13
Fig. 6—Closed Flue Mantel
Clearances with Hood
Maximum
10"
Maximum
2.5"
Minimum
10"
4" Sheet
Metal Hood
Vent-Free Gas Log Heater User Manual
Combustible
Mantel
Minimum
18"

Publicidad

Tabla de contenido
loading

Productos relacionados para Pinnacle Climate Remington REM-L180ALT-F

Tabla de contenido