Operation—REM-L180ALT-F / REM-L180ANT-F / REM-L240ALT-F / REM-L240ANT-F
1. STOP! Read all the above safety information before proceeding.
NOTE: When used as a vented decorative appliance, use of the
thermostat function is prohibited—operate manually only.
2. Turn the control knob clockwise
(see Fig. 26).
3. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B" in
the safety information above. If you don't smell gas, go to the
next step.
4. Turn the control knob counterclockwise
position. Depress control knob.
5. With control knob depressed, push down on the ignitor button
until the pilot lights. The pilot is located behind the heater
screen near the rear of the burner (see Fig. 27).
• Do not attempt to light the pilot by hand.
6. Keep the control knob depressed for (30) seconds after the
pilot lights. Then release the control knob.
• If the control knob does not pop up when released, stop and
immediately call a qualified service technician or gas supplier.
• If the pilot goes out, repeat steps 3 through 7. Wait (1) minute
before attempting to light pilot again. If after several tries the pi-
lot still goes out, turn the gas control knob clockwise
the "OFF" position and call a qualified service technician.
7. Turn the control knob counterclockwise
setting.
WARNING
WARNING
1. Turn the control knob clockwise
Shutting Off the Burner Only (Pilot Stays Lit):
1. Turn the control knob clockwise
THERMOSTATIC CONTROL OPERATION
The thermostatic control valve on this heater is different from standard thermostats. Standard thermostats simply
turn the burner on and off. The thermostat sensing bulb on the control valve used on this heater senses changes
in room temperature and varies the flame accordingly. The burner will shut off completely when the room
temperature exceeds the set temperature. When the room temperature drops below the set temperature, the
unit will cycle back on. The control knob can be set to the desired comfort level between 1 and 5.
©2017 Pinnacle Climate Technologies
LIGHTING INSTRUCTIONS
The fireplace screen must be in place while the heater is in operation.
Any glass doors must be completely opened while the heater is operating.
TO TURN OFF GAS TO THE HEATER
to the "OFF" position
to the "PILOT"
to
to the desired
to the "OFF" position.
to the "PILOT" position.
23
Fig. 26—Control Knob
Fig. 27—Pilot
Vent-Free Gas Log Heater User Manual