3) Programming SRCH / SRCW
Each transmitter is recognised by the control unit by means of an une-
quivocal "code". A "memorisation" phase must therefore be performed in
order to allow the control unit to recognise each single transmitter.
!
• All the memorisation sequences are timed, that is, they
must be completed within the programmed time limits.
When the memory contains no codes the first radio control unit can be entered as follows:
Table "A1"
Memorizing the first transmitter in mode I
1.
As soon as the control unit is powered, 2 long beeps will sound.
2.
Within 5 seconds press and hold down either key 1 or 2 (or key 3 or 4) on the transmitter
to be memorised (for approx. 3 seconds).
3.
Release the key when you hear the first of the 3 beeps confirming memorisation.
N.B.: If there are already transmitters memorised in the control unit, short beeps will sound when it is switched on. This means that the
above procedure is not valid and another memorisation procedure must be used (Table "A2").
When one or more transmitters have already been memorised, others may be enabled as follows:
Table "A2"
Memorizing other transmitters in mode I
1.
Press and hold down either key 1 or 2 (or key 3 or 4) on the new transmitter until you hear a
beep (after about 5 seconds), then release it.
2.
Press any key of a just functioning transmitter slowly 3 times.
3.
Press either key 1 or 2 (or key 3 or 4) on the new transmitter again and release it when you
hear the first of the 3 beeps.
N.B.: If the memorization procedure is successful 3 long beeps will sound. 6 beeps will sound when the memory is full (30 transmitters),
telling you the transmitter cannot be memorised.
If you need to delete all the data contained in the memory of the
control unit, carry out the procedure on table "A3".
The memory can be deleted:
• with a non-memorised transmitter by beginning the procedure
from point A, even if a transmitter which has already been memo-
rised is necessary at point 1.
• using a previously memorised transmitter starting the proce-
dure from point N. 1
Table "A3"
Erasing the memory in mode I
A
Switch the control unit off and cut the jumper on the weld side of the card (see fig. 12).
The jumper must be reconstituted when the deletion procedure has been completed.
B
Power the control unit and wait for the initial beeps
1
Press and hold down key 2 (or 4) of a previously memorized transmitter until you hear a beep
(after about 5 seconds) then release it.
2
After 1 second press the same key again and release it exactly during the third beep.
3
After 1 second press the same key again and release it exactly during the third beep
4
After 1 second press the same key again and release it exactly during the third beep.
5
If you wish to delete all the data in the memory, press the same key again within 2 seconds
until you hear the first of 5 beeps, then release them
N.B.: 5 beeps will indicate that all the codes in the memory have been deleted.
18
• Programming via radio may be done on all the control units
within the range of the transmitter; therefore, only the one
involved in the operation should be kept switched on.
Two keys are used on each transmitter: key 1 = „ON" and key 2 =
„OFF". In those transmitters with 4 keys, those which remain "empty"
can be used to control another control unit: key 3 = „ON" and key
4 = „OFF".
The following can be erased:
• only the transmitter codes, finishing at point N. 4
• All the data (transmitters and timer programming), completing the
procedure up to point N. 5.
Example
3s
Example
New
5s
Old
X3
New
Example
1-3
5s
www.stobag.com