Descargar Imprimir esta página

Grohe Ondus 36 059 Manual Del Usuario página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

Application
Operating panel for use with concealed faucet body 36 068 in
conjunction with function unit 36 072.
Specifications
• Automatic safety shut-off (factory setting):
• Safty stop (factory setting)
• Type of protection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage
and rated current.
Installation
Cut faucet template (A) to length, see fold-out page II,
fig. [1].
Wall adapter, see fold-out page II, figs. [1] to [4].
1. Guide plug-in connector (B) of function unit 36 067 through
wall adapter (C), see fig. [2].
2. Insert wall adapter (C) and turn through 45°, see fig. [3].
The faucet depth of wall adapter (C) can be adapted to the
wall thickness by turning the internal screws (C1).
3. Align wall adapter (C) and tighten internal screws (C1),
see fig. [4].
Operating panel, see fold-out page II, figs. [5] and [6].
1. Attach plug-in connector (B) of the function unit to plug-in
connector (D1) of operating panel (D) and push back into
the concealed faucet body, see fig. [5].
2. Insert operating panel (D) in wall adapter (C).
3. Fasten operating panel (D) using set screws (E), see fig. [6].
1
English
Operation
Using the operating panel
Start/Stop Button
Operational readiness of faucet. Water flow
commences following actuation of a programme
button. Repeated actuation stops water flow. The
connected ports can be operated simultaneously.
Pause button
Interrupts the flow of water (temperature arrow on
operating panel orange). The flow is resumed by
pressing the button again.
30 min.
The faucet switches off automatically after a preset
102 °F
time in pause mode (factory setting 60 s).
IP 57
Temperature
Increases (red arrow, left) or decreases (blue arrow,
right) the water temperature.
The display flashes until the preset temperature is
B
reached.
2
Volume
2500 V
Increases
212 °F
eight stages.
Temperature safety button
Overriding the safety stop (factory setting: 102 °F).
The actual value is synchronised with the display at 100 °F.
See Calibrate in the section Setting mode.
Programme buttons
Drench shower head
Head shower
Side shower
Hand shower
Bath inlet
Memory button 1
Memory button 2
- In the delivery condition, all programme buttons appear on
the operating panel.
- In setting mode under Ports, a maximum of three different
programme buttons can be allocated to the ports. The
solenoid valves of the unused ports can be switched off.
- The memory button functions can be adapted or changed in
setting mode under Preset.
- The bars on the display illustrate the chronological
sequence of the relevant programme.
or decreases the flow rate in a total of

Publicidad

loading