The warranty does not cover failures due to:
• normal wear and tear;
• improper handling, installation and use;
• use with incorrectly connected control systems;
• work done by unskilled staff;
• use of non-genuine spare parts.
warning!
Any modifications made to the product without the manufacturer's authorisation may cause hazards and lead to a deterio-
ration in performance and loss of warranty cover.
The responsibility of repair, overhaul or maintenance to the pump in -Ex versions lies with the user of the product: make sure
that any interventions is carried out by an Ex-Certified Service Centre (according with international and/or local standards and
rules) or by a Zenit Service Centre.
1.8 Storage
During storage, the electric pump must be kept in a suitable place, out of the reach of children or those with diminished responsibility,
suitably secured against falling and protected from damp, vibrations, dust and extreme temperatures (below -20°C/-4°F and above
+60°C/140°F).
If the pump should freeze, do not use flames to remove the ice; immerse it in the liquid in which it is to be installed until it thaws out.
warning!
Turn the impeller by hand occasionally (at least every 2 months) through the outlet or intake, to prevent the mechanical
seals from sticking together.
1.9 Technical data
The product's technical data and characteristics are provided in the technical data sheet.
1.10 Operating conditions
For correct use, comply with the following operating conditions:
• Liquid/Ambient temperature: 0 ÷ 40°C
• pH value: 6 ÷ 14
• Duty service: S1 operation (continuous operation), the pump must always operate fully submerged
• Starts per hour mode: maximum 20 for motor with rated power P2 up to 10 kW, 15 for P2 over 10 kW
The -Ex version pump can be used with a frequency converter (inverter) with the compulsory condition that the thermal protec-
tor inside the motor are correctly connected to the control panel (for non -Ex panels, outside of the risk area).
1.11 Nameplate
On the motor cover you find a metal plate which states the operating data and approvals applying to the pumps.
With this manual, a sticky label containing the product features found on the metallic plate affixed to the electric pump has been provided.
We recommend that you put this label in the specific place provided within the manual and then refer to the data contained on the label for any
requirements or information.
Zenit Italia s.r.l.
via dell'Industria, 11
I-41018 S.Cesario s.P. (MO)
zenit.com
1
3
6
7
8
12
11
15
16
18
Ex db IIB T4 Gb
23
17
II 2G Ex h IIB T4 Gb
WARNING: See user manual
20
WARNING: Flameproof joints cannot be repaired
21
Fig. 1 A - single phase
1. Product name
2. Serial number
3. Product version
4. Year of manufacture
5. Weight
6. Rated voltage
6A. Voltage and current
(delta connection)
6B. Voltage and current
(Y connection)
7. Motor phases
25
XXXX
EPT XX ATEX XXXX X
2
5
4
9
10
13
14
19
22
24
8. Frequency
9. Motor power output - P2
10. Power factor
11. Rated current
12. Run capacitor
13. Start capacitor
14. Rpm
15. Motor insulation class
16. Duty type
First installation manual – Translation of original instructions
Zenit Italia s.r.l.
via dell'Industria, 11
I-41018 S.Cesario s.P. (MO)
zenit.com
1
3
7
6A
6B
15
16
18
Ex db IIB T4 Gb
23
17
II 2G Ex h IIB T4 Gb
WARNING: See user manual
20
WARNING: Flameproof joints cannot be repaired
21
Fig. 1 B - Three phase
17. IEC protection class against electric shock
18. Maximum immersion depth
19. Maximum and minimum head
20. Maximum ambient temperature
21. Casing protection rating
22. Minimum and maximum flow-rate
23. -Ex protection classification
24. Motor reference standards
25 -Ex certification number
25
XXXX
EPT XX ATEX XXXX X
2
5
4
8
9
10
14
19
22
24
EN
17