4 - TECHNICAL SPECIFICATIONS
Power supply
Max motors load
Duty clcle
Consumption in stand-by
(with LOW ENERGY module installed)
Max accessories load 24V
Protection fuse
Weight
Dimensions
Working temperature
Protection
CITY1-EVO
230V / 50Hz
2 x 700W
40%
0,45 W
10W
5A
1600 g
295 x 230 x 100 mm
-20 ÷ +60°C
IP55
- 17 -
5 - DESCRIPTION OF THE CONTROL
UNIT
The digital control unit CITY1-EVO is an innovative V2 product
that guarantees a safe and reliable automation of leaf swing or
sliding gates.
CITY1-EVO is provided with a display that, not only makes
programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.
In compliance with the European standards concerning electrical
safety and electromagnetic compatibility (EN 60335-1,
EN 50081-1 and EN 50082-1) it has been equipped with the low
voltage circuit total electric insulation (motors included) from the
network voltage.
Other characteristics:
• Automatic control for the null current relay switch
• Allows to control ENCODER-equipped 230V motors
• Power adjustment with independent wave shutting on both
the two motors
• Obstacle detection by means of monitoring start condenser
voltage
• Automatic learning of the operation time
• Operation by means of mechanical ends of stroke connected to
the gearcase or connected in series to the motor
• Tests for safety devices (photocells, safety edges and triacs)
before each opening (as required by the referred regulations)
• Deactivation of safety inputs through the configuration menu:
no jumper is required for terminals concerning safety devices
that have not been installed, yet. You will only need to disable
this function from its relevant menu
• Control unit programming can be locked through the optional
CL1+ key
• ADI 2.0 connector for the advanced management of the ADI
devices.
• USB connector to connect the control unit to a PC and manage
through software the programming of the unit, the firmware
updates and the operation diagnostics.
• Connector for the LOW ENERGY module that allows saving
electrical energy: when the gate is standing the LOW ENERGY
module deactivates the display, the photocells and all the
devices power supplied by a terminal box.
To activate the operation of the module, it is necessary to
activate the ENERGY SAVING function (parameter
EnSA
Si
=
).