Shut off hot and cold water supply.
II. Solenoid valve
1. Remove screw (I), see Fig. [7].
2. Pull out cartridge (J).
3. Remove screw (L) and detach solenoid valve (M) with
adapter (N), see Fig. [8].
4. Remove plate (O) and pull solenoid valve (M) out of
adapter (N).
5. Remove filter (S).
Reassemble in reverse order.
When inserting into adapter (N), solenoid valve (M) must be
turned clockwise against the stop.
Ensure that seals of adapter (N) engage in the grooves on the
housing. Fit screws (L) and tighten evenly and alternately.
III. Filter
1. Unscrew connection hose and remove adapter (B),
see Fig. [9].
2. Remove filter (B1).
Reassemble in reverse order.
IV. Unscrew and clean aerator (42 832) , see fold-out page I.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Battery without contact
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Installation mode active
• Battery discharged
Pulsating water jet
• Battery almost discharged
Water flows
• Solenoid valve defective
continuously
Water quantity too
• Water supply restricted
low
• Filter upstream of solenoid valve dirty
• Filters in the union connection set
blocked
• Non-return valve defective
• Service valves not fully open
Incorrect mixed
• See Water quantity too low
temperature
• Incorrect setting of temperature limiter
• Limescale on mixer spindle
Reassemble in reverse order.
V. Mixer spindle
1. Detach fitting from connections.
2. Remove fitting from basin.
Removal is as described in section "Setting temperature
limiter" points 1 to 3, see Figs. [5] and [6].
3. Remove screw (U) from housing using a 2.5mm allen key.
4. Pull out mixer spindle (H).
Reassemble in reverse order.
Screw (U) must engage in groove (H1) of mixer
spindle (H).
Replacement parts, see fold-out page I ( * = special
accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean contacts, see Cartridge maintenance
- Open shut-off valves
- Clean, see Solenoid valve maintenance
- Replace, see Solenoid valve maintenance
- Press actuating cap twice (double click)
- Replace, see Cartridge maintenance
- Replace, see Cartridge maintenance
- Replace, see Solenoid valve maintenance
- Check supply lines
- Replace, see Solenoid valve maintenance
- Replace, see Non-return valve maintenance
- Replace, see Non-return valve maintenance
- Fully open shut-off valves, service valves
- Setting, see Setting temperature limiter
- Clean, see Mixer spindle maintenance