Mechanical
Process Connection
• thread
• optional sliding bushing
• thread material
Tines
• tine material
1
(PTFE
coated tines are available upon special request. Contact your local Siemens
Milltronics representative for ordering information.)
Enclosure
• construction
• conduit entry
• ingress protection
Weight
• standard version, no extensions
• solids/liquids, no extensions
Environmental
• location
• altitude
• ambient temperature
• relative humidity
• installation category
• pollution degree
Process
Temperature
• All approvals except CSA Class II, Group G:
• CSA Class II, Group G:
• For applications with process temperature greater than 80 °C (176 °F), the
maximum threaded bushing surface temperature must not exceed 80 °C (176 °F)
• Maximum enclosure surface temperature (Category 2D): 90 °C (194 °F) (ATEX
relevant)
• Maximum extension surface temperature (Category 1D): 150 °C (302 °F) (ATEX
relevant)
1.
Polytetrafluoroethylene
7ML19985FT61
SITRANS LVS200 – INSTRUCTION MANUAL
1½" NPT, 1½" BSP
with 2" NPT or BSP thread
stainless steel 303 (1.4305)
stainless steel 316Ti (1.4571)
epoxy-coated aluminum
2 x M20x1.5, or
2 x ½" NPT
Type 4 / NEMA 4 / IP65
2.0 kg (4.4 lb)
1.9 kg (4.2 lb)
indoor/outdoor
max. 2000 m (6562 ft)
–40 to 60 °C (–40 to 176 °F)
0 to 100% (suitable for outdoor: ingress
protection: Type 4 / NEMA 4 / IP65
III
2
–40 to 150 °C (–40 to 302 °F)
–40 to 140 °C (–40 to 284 °F), CSA
temperature code T3B