6
Outputs
6.1
Output 1 and output 2
Optocoupler with open emitter and collector
6.2
Output 3 to output 6
Optocoupler with open collector and common
emitte.
6.3
Active Outputs
An active output will be shown on the display as
,
,
,
For safety switching the optocoupler outputs can be
inverted, i.e. the optocoupler is disabled when the
presets are reached. To do this, the parameters
Pr.OUT1 to Pr.OUT6 must be set to
permanent signal) or
signal).
7
Programming
7.1
Entering the programming
Press the Reset key and
Prog/Mode key simultaneously
for 3 s
Programming can be exited
again using the Prog/Mode key.
Press key T2 to continue with the
programming
Enter the main menu by pressing
the Prog/Mode key
7.2
Choice of main menus
The menus are selected using
the keys T2 (next) and T1 (back)
www.kuebler.com
,
or
.
(for
or
(for timed
The security prompt
appears in the display
The security prompt
appears in the display
7.3
Entering a sub-menu
The sub-menu is opened with the
Prog/Mode key and the first
menu item is displayed.
7.4
Selecting the menu items
The Prog/Mode key is used to
select a menu item within the
sub-menu
7.5
Setting the menu items
The T2 key is used to select the
individual settings for the menu
items
When setting count values, each
decade has a key assigned to it.
Each time the key is pressed,
the value increments by one
7.6
Accepting the setting
Pressing the Prog/Mode key
causes the current setting to be
accepted. Programming then
switches to the next menu item.
7.7
Ending the programming
During programming, it is possible to exit the
programming at each menu item by pressing the
reset key.
Press the Reset key
Pressing the Prog/Mode key
acknowledges this prompt and
causes the programming menu
to start again from the beginning.
The previously-programmed
values are preserved. These can
now be changed or checked
again.
Pressing the decade key T2
selects the termination of the
programming
The security prompt
appears in the display
The security prompt
appears in the display
Page 7