4. GROUPS
Interfaces can be configured with a group (from 0 to 7) so that there is no interference when
working near each other. Useful for working with the system HF.
4.1.
GROUP CONFIGURATION
To configure the group, the PROG pins should be short-circuited and a tag activation should be
make. The interface will be configured with the first tag activated in hands free mode. If you
work with transmitters, these will always be configured with group 0.
Operations
On powering the interface, the led TX will flash the same number of times as the group
number with which it is configured.