Descargar Imprimir esta página

Oxyline 1012 P2 R Manual De Usuario página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
A copy of the declaration for this product is available online at:
The product conforms to Regulation (EU) 2016/425 of the European Parliament and of the Council of 9 March 2016 on personal
protective equipment and repealing Council Directive 89/686/EEC.
The product conforms to the following harmonised standard:
INTENDED USE
1012 P2 R filters, when completed with an appropriate two-filter half mask or mask, protect the respiratory system against
particulate aerosols (dusts, flumes) and liquid aerosols (mists) as long as the concentration of the dispersed aerosol phase does not
exceed:
For the 1012 P2 R filter – 10 x OEL (Occupational Exposure Limit), if assembled with a half mask, and 16,5 x OEL, if
assembled with a mask.
RECOMMENDATIONS RESTRICTIONS ON THE USE:
1.
Filters should be used only in accordance with this instruction manual that includes the correct selection, use and storage.
2.
Filters should be used with half masks or masks equipped with appropriate bayonet holders:
Half masks: OXYLINE X1000, OXYLINE X1200;
Full masks with a bayonet connection identical to the OXYLINE connection
The use of filters mentioned in this manual with other face masks requires appropriate control tests to be carried out.
3.
When assembled with an appropriate half mask or mask, these filters protect the respiratory system against harmful and toxic
substances in the form of solid and liquid aerosols (dusts, fumes, mists).
NOTE: Half masks and masks assembled with 1012 P2 R filters do not protect against carbon monoxide. Do not use
half masks with filters near fires.
4.
Masks and half masks assembled with 1012 P2 R filters must not be used if oxygen deficiency occurs (below 18% vol.), e.g. in
wells, ducts, and non-ventilated rooms with small cubature.
5.
If during the use of the filters you feel a significant increase in breathing resistance, leave the affected area and replace both
elements at the same time.
6.
Before use, absorbers should be stored only in the original packaging.
7.
Half-masks and masks with filters 1012 P2 R should not be used where there may be a lack of oxygen (below 18% by
volume), e.g. in wells, canals, unventilated rooms with low volume.
FIXING INSTRUCTIONS:
1.
Place the filter opening on the half mask / mask connector so that the connector tabs fit into the filter opening. One of the
tabs is narrower and the hole fits the connector in one position only. Press the filter against the half mask - the connector
tabs will hide inside the filter.
2.
Turn the filter clockwise until it stops.
STORAGE
1012 P2 R filters should be stored in dry rooms, free of harmful vapours and gases, where temperature is maintained from -5 to
+40°C and relative humidity is below 80%. The filters should not be stored together with the substances that release unpleasant
odours, as well as the substances that are toxic and aggressive to the materials from which the absorber filters are made.
WARRANTY
Filters stored in original packaging keep their useful (protective) properties for 60 months from the production date.
LABELING
The following markings appear on the filter surface:
• Product name: 1012 P2 R;
• Product class: P2 - class 2;
• R - reusable;
• EN 143: 2000 - standard number;
• CE mark with the number 1437 notified body;
• company logo with the company name;
• manufacturer's address;
• a mark with an arrow indicating the mounting method;
• date of production being also the batch number;
• expiration date.
OXYLINE Sp. z o.o. ul. Piłsudskiego 23, 95-200 Pabianice, POLAND tel: +48 42 215 10 68, fax +48 42 203 203 1
e-mail: oxyline@oxyline.eu www.oxyline.eu
1437 Central Institute for Labour Protection – National Research Institute; Czerniakowska 16, 00-701 Warsaw, Poland
Version of the manual from 06/03/2020
USER MANUAL FILTER 1012 P2 R
www.oxyline.eu/deklaracje.html
EN 143:2000, EN:143:2000/A1:2006

Publicidad

loading