Care And Maintenance - Homewerks Worldwide 3210-150-CH-B-Z Guia De Inicio Rapido

Cuenca del grifo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ASSEMBLY INSTRUCTIONS
8. Important: After installation is
completed, remove aerator. Turn
on water supply and allow both
hot and cold water to run for at
least one minute each. While
water is running, check for leaks.
Replace aerator. Tighten nuts
slightly to stop minor leaks. If
problems persist, refer to
troubleshooting chart.
OPERATION INSTRUCTIONS
This faucet is a single temperature faucet. Depending on
what you hooked the faucet to, it will either be all COLD or
all HOT water.
Turn faucet handle to the left to turn on, to the right to turn
water off.

CARE AND MAINTENANCE

Clean periodically with a soft cloth. Avoid abrasive cleaners,
steel wool, and harsh chemicals as these will dull the finish
and void your warranty.
TROUBLESHOOTING
PROBLEM: Leaks underneath handle.
POSSIBLE CAUSE: Bonnet has come loose or O-ring on
cartridge is dirty or twisted.
CORRECTIVE ACTION:
1. Move the handle to the off position. Unscrew the handle
screw and remove the handle.
2. Tighten the bonnet by turning it clockwise. Move the
cartridge stem to the on position. The leak should stop
draining out from around the cartridge stem.
3. If the leak does not stop, shut off the water supply.
Remove the bonnet by turning it counter-clockwise. Lift
out the cartridge valve. Inspect the larger O-ring on the
cartridge bonnet and the smaller O-ring on the cartridge
stem. Remove any debris from the O-rings. If either O-ring
is twisted, straighten it out. If either O-ring is damaged,
replace the cartridge by calling Customer Service.
4. Position the cartridge back into the faucet body. Make
sure the ridges on the two sides of the cartridge bonnet
fit into the grooves on the two sides of the faucet body.
Tightly screw the bonnet onto the faucet body.
5. Re-install the handle.
PROBLEM: Water does not completely shut off.
POSSIBLE CAUSE: Rubber valve seat is dirty, stuck, or
broken.
CORRECTIVE ACTION:
1. Shut off the water supply to the faucet that leaks.
2. Remove the handle on the problem side. Loosen the
bonnet by turning it counterclockwise. Lift out the
cartridge assembly.
3. Inspect the rubber valve seat in the faucet body. If there is
debris or brass scrap on the surface of the seat, remove
www.homewerksww.com
8
To get a blended temperature, you must have two spigot
faucets installed, one hot and one cold. Place plug in the
sink basin, turn on the hot and cold water to fill the basin.
Adjust the water temperature in the basin by adding more
or less hot or cold water.
it. If the rubber seat is stuck tightly in the water inlet hole,
push it gently with a fingertip so that it moves up and down
smoothly. The spring (smaller end up) must be replaced
underneath the valve seat. If the rubber valve seat is worn
out or broken, replace the cartridge by calling Customer
Service.
4. Replace the cartridge in the faucet body. Make sure that
the ridges on the two sides of the cartridge bonnet fit
into the grooves on the two sides of the faucet body.
Tightly screw the bonnet onto the faucet body.
5. Re-install the handle.
PROBLEM: Faucet leaks around aerator.
POSSIBLE CAUSE: Aerator incorrectly fitted.
CORRECTIVE ACTION:
1. Unscrew the aerator by turning it clockwise. Inspect the
black rubber packing inside the aerator. The rubber
packing should be flat.
2. Screw the aerator onto the spout end and tighten.
PROBLEM: Improper water pattern.
POSSIBLE CAUSE: Aerator dirty or small parts inside
aerator improperly installed.
CORRECTIVE ACTION:
1. Remove the aerator from the spout end by turning it
clockwise.
2. Gently flush the small parts inside the aerator to clear
away any debris.
3. Re-install the small parts as shown in the exploded
diagram. Metal screens must be flat and plastic supporter
must be straight.
4. Screw the aerator onto the spout end and tighten.
3

Publicidad

Tabla de contenido
loading

Tabla de contenido