Fittings And Valves; Electrical Requirements - Pentair LA STA-RITE HD Serie Guia Del Usuario Y Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

FITTINGS AND VALVES

1.
Do not install 90° elbows directly into pump inlet.
2. Flooded suction systems should have gate valves
installed on suction and discharge pipes for main-
tenance, however, the suction gate valve should
be no closer than five times the suction pipe di-
ameter as described in this section.
3. Use a check valve (non-return valve) in the dis-
charge line when using this pump for any appli-
cation where there is significant height to the
plumbing after the pump.
4. Be sure to install check valves when plumbing in
parallel with another pump. This helps prevent
reverse rotation of the impeller and motor.
3.4 - START / OPERATION
Starting the pump
• Fill pump strainer with water to suction pipe level.
• Lubricate the lid Oring with lubricant each time it
is removed.
• Make sure the strainer lid is properly closed before
turning on the pump.
• Energize the motor, the pump will prime. The prim-
ing time depends on the suction lift and distance to
Maintenance
The strainer basket should be weekly removed and cleaned. Never operate the pump without its strainer basket.
Component
Warning pictograms
Water supply
Safety devices
Gerneral condition of the pump
Cooling ribs of electric motors
Electrical equipment
Preliminary filter housing
O-Ring in preliminary filter cover
Winterizing
• Protect the pump from freezing.
• Remove all plugs and drain the pump and all piping.
• Store drains and plugs in the strainer basket.
• Remove the pump to a dry and warm room.
• Do not wrap the motor with plastic covering as con-
densation may damage the pump.
PUMP INFORMATION

ELECTRICAL REQUIREMENTS

1.
2. A means for disconnection must be incorporated
3. Do not mount electrical controls directly over
• Pump will not lift more than 2,5 meter. If pump does
• Avoid damage on your pool products by installing
Check
Visual check
Check lines and
connections
Visual check
Visual check
Clean the colling ribs to
maintain the colling effect
Check
Check housing for dirt
Visual check
• In installations where the pump can not be drained,
• Do not use other anti-freeze solutions, these are all
Install all equipment in accordance with
the National Electrical code and all ap-
plicable local codes and ordinances.
Sufficient equipotential bonding (min. 4.5mm²
recommended), in accordance with local regula-
tion, is required on all metal components of the
pool including the pool pump. It is required for
electrical safety as well as to reduce the risk of
corrosion.
in the fixed wiring in accordance with the wiring
rules.
pump.
the pool. Five minutes is a reasonable time.
not prime, see troubleshooting guide.
water treatment produts (chlorine/ph/pumps/...)
behind other equipment.
Interval
Remarks
Monthly
Replace if necessary
Monthly
Replace any damage immediately
Ensure correct installation /
Monthly
refitting
Look out for any corrosion or
Half-yearly
damage
Half-yearly -
Rectify loose connections or
singed cables immediately. Have
Monthly
all faults repaired by a qualified
electrician
Weekly
Remove all dirt thoroughly
Half-yearly -
a 40% propyleneglycol, 60% water solution will pro-
tect to -46°C.
highly toxic and will damage the pump.
Single speed pumps Installation and User' s Guide
9

Publicidad

Tabla de contenido
loading

Tabla de contenido