Initial prime
Air pressure at zero
1 Connect a product hose to the pump's
fluid outlet.
2 Direct the hose into an appropriate collec-
tion container.
3 Place the pump in the fluid to be
dispensed.
4 Slowly supply air pressure to the pump's
motor.
5 Allow the pump to cycle slowly until the
fluid is free of air.
!
Notice
Pump does not prime, refer to
Troubleshooting Chart, pg 10.
Motor leaks, refer to
Air motor Troubleshooting Chart,
page 18 for details.
W A R N I N G
Disconnect air to motor if leakage occurs
anywhere within system.
Failure to comply may result in serious
personal injury and/or death.
Leakage and Stall
With air pressure at zero:
1 Attach a control valve to outlet hose of
the pump.
2 Open nozzle on control valve.
3 Slowly supply air pressure to
pump motor.
4 Allow pump to cycle slowly until fluid is
free of air.
5 Set air pressure to normal
operating pressure.
6 Operate control valve into a container.
7 Shut off control valve.
8 Visually inspect pump for
external leaks.
9 Check motor for air leakage.
!
Notice
Pump should not cycle more than
once or twice in one hour.
Installation
Additional items that should be incorporated
into air piping systems are listed in table 1.
Air line components
Part No.
Description
602134
Regulator and gauge
combination
9
Table 1