Pre-Assembly (continued)
GRouNDING INSTRuCTIoNS
this heater is for use with 120v power sources . the cord has a three-blade, grounding-type
plug . an adapter is available for connecting three-blade grounding-type plugs to two-slot
receptacles . the green grounding lug extending from the adapter must be connected to a
permanent ground, such as a properly grounded outlet box . the adapter should not be used if
a three-slot grounded receptacle is available .
DETERMINING THE MouNTING LoCATIoN
When choosing a location for your new fireplace, ensure the general instructions are followed .
For the best effect, install the fireplace out of direct sunlight . it is safe to set the fireplace
insert close to non-combustibles .
do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance .
WarninG:
FIREBoX SPECIFICATIoNS
Model No.
dimensions W x d x h
net Weight / Gross Weight
voltage
Frequency
Watts / amps
Fireplace rating
ELECTRICAL CoNNECTIoN
a 15 amp, 120 volt, 60 hz circuit with a properly grounded outlet is required to operate this appliance . Preferably, the fireplace insert
will be on a dedicated circuit, as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when
the heater is in operation . the unit comes standard with a 6 ft (1 .8 m) long 3-wire cord, exiting out the back of the fireplace insert . Plan
the installation to avoid the use of an extension cord . if an extension cord must be used, it must be a minimum 14-gauge, 3-wire with
grounding type plug and connector, and must be rated not less than 1875 watts . the extension cord shall not be more than 20 ft (6 m) in
length .
WarninG: electrical outlet wiring must comply with local building codes and other applicable regulations to reduce
the risk of fire, electrical shock, and injury to persons .
WarninG: do not use this fireplace insert if any part of it has been under water . immediately call a qualified service technician to inspect the
firebox and replace any part of the electrical system which has been under water .
GLASS INFoRMATIoN
1 . Under no circumstances should this product be operated with a broken or chipped glass panel .
2 . do not strike or slam the glass .
3 . do not use abrasive cleansers to clean the glass .
4 . this product uses tempered glass . replacement of the glass supplied by the manufacturer should be done by qualified/authorized
service personnel only .
MFB25WsC-1
25 in . x 10 .4 in . x 18 .5 in . (63 .3 cm x 26 .5 cm x 47 cm)
27 .7 lbs / 31 lbs
(12 .6 kg / 14 .1 kg)
120v
60 hz
1400 W / 11 .6 a
1400 W / 4777 BtUs
6
Grounding Pin
Cover of Grounded Outlet Box
Adapter
Metal
Grounding Lug
Screw
Cover of Grounded Outlet Box