Normal Operation
Under normal operation the Beacon will Flash when a combination of the four control inputs are connected to +Vdc. The Beacon is OFF and in a low power Standby Mode after 10 seconds of no active control inputs.
No Operation
No Power;
Check Red main Power feeds have a solid connection with +Vdc present on the wire post fuse. A minimum of +9Vdc is required. Replace fuse if necessary.
Verify Red main Power feeds have not exceeded voltage cutoff threshold of +32Vdc. Lower voltage to regain operation.
Check Black main Ground feeds have a solid and low resistance connection to ground.
No Lights;
Verify at least one of the four control inputs is present with +Vdc.
Verify pattern is able to advance and control wire is not set to a Low power mode, pattern 50-51. (Blue wire default)
Perform product configuration (pg. 5).
No or Incorrect Warning Light Flash
No operation;
Verify correct Control Input wire is present with +Vdc.
Verify pattern is able to advance and control wire is not set to a Low power mode, pattern 50-51. (Blue wire default)
Perform product configuration (pg. 5).
Incorrect/Undesired operation;
Check that another control input is not active which has Flash priority over current control input. (pg. 4).
Low Power and Scene Light override flashing mode regardless of wire priority. Remove Low Power or Scene light control input.
No or Incorrect Scene Lights
No Lights;
Verify correct Control Input wire is present with +Vdc.
Verify pattern is able to advance and control wire is set to pattern 45-49.
Perform product configuration (pg. 5).
Incorrect/Undesired operation;
Check that another control input does not have an active Scene with priority over current control input. (pg. 4). Low Power overrides Scene Light wire priority. Remove Low
Power control input.
No or Incorrect Synchronization
No or Incorrect syncing;
Verify green wires are connected between all required Sync 2 products.
Verify Flash patterns are set to the same one. Patterns 12-42 are sync capable with all Sync2 product.
Depending on led module count, Random and rotating patterns (0-11) may not sync correctly between products (ex. Mini-Lightbar & Dual Stack Beacon). Scene, Cruise or Low
Power are not sync capable.
Erratic Flash
Verify Flash patterns are set to the same one.
Check that the green and/or white wire is not being intermittently shorted to ground. Securely seal all connections.