Additional Safety Precautions
1. Know the pump applications, limitations, and potential hazards.
2. Make certain the electrical power source is adequate for the requirements of the pump.
3. ALWAYS disconnect the power to the pump and drain all water from the system before servicing.
4. Secure the pump on a solid base to prevent the pump from tipping over and possibly falling into
the water.
5. Secure the discharge hose before starting the pump. Pump torque may cause an unsecured
discharge hose to "whip", possibly causing personal injury and/or property damage.
6. Before using the pump, check the hose for holes or excess wear, which could cause leaks, and be
sure hose is not kinked or making sharp angles. A straight hose allows the pump to move the
greatest amount of water quickly.
7. Check that all hose connections are tight to minimize leaks. Ensure all hose washers are in place.
8. Connect the pump DIRECTLY to a grounded, GFCI outlet.
9. Extension cords may not deliver sufficient voltage to the pump motor. If an extension cord must be
used, use no more than a 25 ft., 3-prong, 16 AWG, outdoor-grade cord.
10. Make certain the electrical circuit to the pump is protected by a 5-amp minimum (15-amp
maximum) fuse or circuit breaker.
11. Periodically inspect pump and system components to be sure pump inlets are free of mud, sand,
and debris. DISCONNECT PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.
12. Wear safety glasses at all times when working with pumps.
13. Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the
workplace, the Occupational Safety and Health Act (OSHA).
14. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an
approved 3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN
UNDER ANY CIRCUMSTANCES. The 3-prong plug must be directly inserted into a properly
installed and grounded 3-prong, grounding-type receptacle. Do not use pump with a 2-prong
wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet)
installed in accordance with the National Electrical Code and local codes and ordinances. All
wiring should be performed by a qualified electrician.
15. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the
cord. Do not use damaged or worn cords.
PERFORMANCE
GPM of Water @ Total Feet of Head with 3/4 in. hose
Model
HP
PPTP1
1/10
PREPARATION
WARNING: Always use handle to lift pump. Never use power cord to lift pump. To avoid
skin burns, unplug and allow time for the pump to cool after periods of extended use.
Before beginning assembly of product, make sure all parts are present. Compare parts with package
contents list. If any part is missing or damaged, do not attempt to assemble the product. Contact
customer service for replacement parts.
10 ft.
20 ft.
4.8
3.9
30 ft.
40 ft.
2.5
1
4
Max. Lift
45 ft.
0