Maintenance
Figure 21
Align
Marks
Figure 22
Figure 23
Bolts should
be easy to
insert.
Make sure
all marks
line up.
Figure 24
Step 3. Make sure that the shaft keys are in place on the shaft. If they are
Step 4. Carefully slide the adapter over the shaft (see Figure 22). Do not
Step 5. Using the alignment marks made before disassembly, line up the
Use pliers –
with care –
no hammers.
Step 6. Push the shaft seal and seal spring onto the shaft, after making
Step 7. Slide the first impeller onto the shaft; follow it with the impeller
Step 8. Install a new volute gasket, lining up the bolt holes with the bolt
Step 9. Install the intermediate volute, aligning it with the mark made
Step 10. Make sure the second shaft key is in place and install the second
Step 11. Install the base volute gasket. Make sure the gasket is right side up
Step 12. Insert the four base capscrews and tighten evenly (see Figure 24).
Step 13. Reinstall the pressure switch barbed fitting and pressure tube.
Step 14. Reinstall the pump on the adapter flange (use a new gasket) and
not, squeeze them in place now with slip joint pliers. Do not tap
them or hit them with a hammer; you could bend the shaft (see
Figure 21). When the keys are correctly installed, the adapter will
pass over the keys without interference.
damage the shaft sealing surface; it is highly polished and any
slight scratches or nicks will ruin it.
adapter with the motor and bolt the adapter in place. Tighten the
cap screws evenly.
sure that the seal faces and shaft are clean. Take care that the shaft
shoulder does not damage the carbon seal face. Follow the seal
spring with the spring holder; compress the spring and give the
spring holder a quarter turn to lock it under the first shaft key (see
Figure 23).
spacer. Twist the impeller on the shaft to make sure that the shaft
key is still in place and the impeller is locked to the shaft (the
shaft should turn with the impeller).
holes in the adapter. Make sure the gasket is right side up so that
the water passage holes line up with the water passages in the
volutes.
before disassembly. Use the long cap screws to check this align-
ment. It cannot be stressed too strongly that all bolt holes and
water passages of all gaskets and volutes MUST line up with each
other, or the pump will not be assembled correctly.
impeller. Twist the impeller to make sure that the shaft key is still in
place. Hold the motor shaft with slip-joint pliers or vice-grips and
install and tighten the impeller locknut. Tightening the lock nut
automatically spaces the impeller correctly. Do not overtighten.
so that the water passage holes line up with the water passages in
the volutes. Install the base volute, using the alignment marks
made before disassembly. Make sure that the pump discharge will
correctly meet the the piping when the pump is reinstalled.
These should be easy to install if everything is correctly aligned. If
not, don't force them; go back over your work and find and cor-
rect the misalignment.
reconnect the wiring and grounding. Pump is now ready for
operation.
13