Electrical
Disconnect power before working on pump, motor, pressure switch, or wiring.
Your Motor Terminal Board (under the motor end cover)
and Pressure Switch look like one of those shown below.
Convert to 115 Volts as shown. Do not change motor
230 Volt to 115 Volt Conversion.
230 V
A
A
L 2
L 2
L 1
L 1
230 Volt to 115 Volt Conversion.
1.
Pull plug
straight
out from
terminal
board.
A
1.
L1
Figure 12: Motor wiring connections through Pressure Switch. Match motor voltage to line voltage
Move plug to change voltage.
Ground
Screw
115 V
A
A
L 2
L 2
L 1
L 1
Power Supply
Wires
Move plug to change voltage.
2.
Plug in again
Ground
with arrow
Screw
on plug
pointing to
'115 Volts'.
2.
A
L1
3962 0401 A
wire before connecting power supply wires. Use the wire size (including
the ground wire) specified in the wiring chart. If possible, connect the
pump to a separate branch circuit with no other appliances on it.
WIRING CONNECTIONS
damage the motor and voids the warranty. The supply voltage must be with-
in ±10% of the motor nameplate voltage.
NOTICE: Dual-voltage motors are factory wired for 230 volts. If necessary,
reconnect the motor for 115 volts, as shown. Do not alter the wiring in sin-
gle voltage motors.
Install, ground, wire, and maintain your pump in compliance with the
National Electrical Code (NEC) or the Canadian Electrical Code (CEC), as
applicable, and with all local codes and ordinances that apply. Consult
your local building inspector for code information.
wiring if line voltage is 230 Volts or if you have a single
voltage motor. Connect power supply as shown for your
type of switch and your supply voltage.
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Connect the green (or bare copper) ground wire
to the green ground screw.
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Hazardous voltage. Can shock, burn, or kill. Connect ground
Explosion hazard. Do not ground to a gas supply line.
Fire hazard. Incorrect voltage can cause a fire or seriously
Clamp the power cable to prevent strain
on the terminal screws.
8