CONNECTION OF FUME EXHAUST VENT
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
Connecting to a flue with
natural draught
To carry out this operation,
proceed as follows.
1 - Connect the appliance's
exhaust outlet to the flue
(A) using a line comply-
ing with the dimensions
shown in the diagram.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
1 - Position the appliance underneath the
hood (B) and connect a line of the dimen-
sions shown in the diagram to the appli-
ance's exhaust outlet.
ELECTRICAL CONNECTION
Important
The connection must be made by authorised,
IT
skilled personnel, in accordance with the rele-
vant legal requirements, using appropriate and
GB
specified materials.
The appliance is supplied with operating volt-
DE
age 230V1N, which cannot be switched to other
values (For version 191BR1GA - 191BR2GA-
191BR3GA only).
FR
Connect the appliance to the
ES
mains electricity supply as
follows.
1 - If not already present, in-
stall a circuit-breaker (A)
with overload cutout and
differential safety break-
er close to the appliance.
English
B
The fan of the extraction system must
switch on automatically when the gas sup-
ply tap is turned on.
The appliance is supplied with operating volt-
age 400V3N, which can be switched to 230V3
(For
291BR3GA only).
Before doing any work, cut off the mains elec-
tricity supply.
A
- 22 -
Important
version
291BR1GA
Caution - warning
D
A
IDM-39603312400.tif
-
291BR2GA-
E
D
IDM-39616201100.tif