Scale-Removal Cycle - Jacuzzi play SPHERE 90 Uso Y Mantenimiento

Ocultar thumbs Ver también para play SPHERE 90:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

I This function ends after 40 minutes, but it can be switched off
at any moment by pressing the button "I/O".
I The recommended length of the steam bath is about 20 min-
utes, even if the total time set by the manufacturer is 40 minutes.
The user can choose to enter the shower enclosure when steam
production begins, or after a certain time, when the temperature
and the amount of steam inside the shower enclosure are increased.
When the steam bath has ended, do not turn off the master switch
for at least 2 minutes, as this will prevent the washing and emp-
tying of the boiler.
WARNING!
Steam is comes out at a temperature of about
100°C. Keep your legs away from the steam outlet during the
steam bath, or at least 40 cm away from the nozzles.

SCALE-REMOVAL CYCLE

To troubleshoot problems caused by lime scale in the boiler, the show-
er enclosure is equipped with a function, which, thanks to the cleaning
action of a specific product, cleans the boiler of any scale deposits.
To guarantee that the boiler is completely cleaned, it is essen-
tial to run a scale-removal cycle about once every 20 "steam
bath" cycles.
The cycle lasts about 10 hours: during this time, it is possible to use the
"alarm" function but not the steam bath, however, the "water jet func-
tions" are still available.
I Prepare the scale removal mixture as indicated.
I Making sure that the shower enclosure is powered, press down
button (3) for about 3 seconds: the LED begins to flash, indicating
the start of the cleaning cycle.
I Unscrew the cap of the anti-limescale nozzle as shown in the
figure (detail 1), insert the conveyor provided (detail 2) and pour
the liquid in the opening.
I At the end of the cycle, the liquid is drained away and the boil-
er is cleaned.
I At this point, the scale-removal cycle has ended: when the LED
on the display stops flashing and its light stays on, the steam bath
can also be used.
N.B. do not turn off the main switch until the anti-limescale cycle is
complete, because this would prevent boiler washing.
If the anti-limescale cycle is started accidentally, turn off the main
switch for a few seconds and then turn it back on, so as to restore the
steam bath operation.
ALARM
Connection to the alarm circuit must be made during installation, by
qualified personnel, in compliance with the instructions set forth in
the installation manual.
I When button (2) is pressed, the alarm signal is activated imme-
diately (bells, buzzers, lights etc.): this lasts about 15 seconds, and
then it automatically stops, however, it can be interrupted at any
moment by pressing the button again.
I If, at the moment the alarm starts and the "steam bath" func-
tion is operating, it is immediately interrupted.
I By pressing button (2) during the "steam bath", this function is
interrupted even if the shower enclosure has not been connect-
ed to an alarm circuit.
12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Play sphere 100Play sphere 120

Tabla de contenido