Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• Low-pressure storage heaters (displacement water heaters)
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, install pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
- recommended
• Water connection
Notes:
- Please follow all applicable local codes when setting the
temperature on the hot water heater, as local municipalities
may have codes limiting the maximum hot water heater
setting to 122 °F.
- Major pressure differences between cold and hot water
supply should be avoided.
- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable
appliances.
Installation
Refer to the dimensional drawings on page 1.
Flush piping system prior and after installation of faucet
thoroughly!
Mount faucet on basin, see Figs. [1] and [2].
• Valve with a groove on the top edge of the cartridge (A) and
in addition marked with COLD should be mounted on the
right (cold water) side, see Fig. [1].
• Valve without a groove on the top edge of the cartridge (A)
and in addition marked with HOT should be mounted on the
left (hot water) side.
1. Push on escutcheon (B), see Fig. [1].
2. Place seal (C) on basin and insert faucet through the holes
of the basin.
3. Push on washer (D) from below.
4. Screw on counter nut (E) and tighten with an 27mm open-
ended wrench.
5. Close the cartridges (clockwise for the hot side and counter-
clockwise for the cold side).
6. Insert swivel spout (F) and secure with clip (G), see Fig. [2].
English
8.3 L/min or 2.2 gpm / 60psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
122° - 140 °F
cold - Right hand
hot - Left hand
Fit handspray, see Figs. [3] and [4].
1. Screw escutcheon (H1) to spray holder (H), see Fig. [3].
2. Insert spray holder (H) through the hole, aligning the
O-ring (H2) with the groove on the flange.
3. Tighten spray holder (H) with mounting set (I).
4. Loosely screw handspray (J) with seal (J2) onto spray
hose (K).
5. Insert spray hose (K) complete with handspray (J) through
the spray holder (H) from above.
6. Install the snap coupling (L) on the end of the spray
hose (K) and tighten by hand, see Fig. [4].
7. Pull the sleeve (L1) of the snap coupling (L) downwards and
fit to the union (M).
8. Tighten spray hose (K) with spray (J1) facing to front.
Mount lever (18 244) or handle (18 733), sold separately,
see Fig. [5].
1. Push on lever (N) or handle (O).
2. Screw the brass nut (P) into the cap until tight.
Hand tighten only!
3. Tighten with screw (R) and screw in cover cap (S).
It is recommended that the lever (N) be installed so they point
away from the spout when in the off position.
Connect faucet, see Fig. [1].
For this purpose the supply must be connected to the angle
stops (or other supply points).
The cold water supply should be connected on the right, the
hot water supply on the left side.
Open cold and hot water supply and check connections
for leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off cold and hot water supply!
I. Ceramic cartridge, see Fig. [6].
1. Unscrew cover cap (S) and screw out screw (R).
2. Unscrew brass nut (P) and pull off lever (N) or handle (O).
3. Unscrew cap (T).
4. Unscrew ceramic cartridge (A) using a 17mm wrench.
5. Change complete ceramic cartridge (A) or O-ring (A1).
Observe the different replacement part numbers of the
cartridges, see page 2.
II. Flow staightener, see page 2.
Unscrew and clean flow regulator (13 955).
III. Diverter, see Fig. [6].
1. Remove clip (G) and pull off spout (F)
2. Unscrew nipple (U) and pull out spacer (V) and diverter (W).
Assemble in reverse order.
Replacement parts, see page 2 ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.