5.1 Equipment in machine kit
The machine packing contains the equipment kit, which includes the following items:
- filter cups with filter restraint ring
- filters for filter cups (single and double doses)
- blind filter for filter cup
- spouts for filter cups (single and double doses)
- press for ground coffee
- braided 900 mm stainless-steel tube for water connection (water supply - water softener)
- rubber drain hose with steel coil for water drain
- 3/8" nipples for hose connection to water supply tube
- cleaning brush for serving units
- pump suction filter (on request)
- braided 600 mm stainless-steel tube for water connection (pump inflow - water softener) -
optional only for external pump
- braided 1600 mm stainless-steel tube for water connection (pump outflow - coffee machine) -
optional only for external pump;
5.2 Prearrangement of water supply
FEEDING lINE
Bring the water feeding tube (of at least 3/8" diameter) up to the machine and install an on-off valve (prefer-
ably of 3/8" ball type) that allows a rapid opening and closing operation. The appliance should be connected
to the water mains using the tube supplied with it. Do not connect the appliance with used tubes.
DRAIN lINE
Provide an inspectable drainage pit on the floor connected with the sink drainage line, suitable for receiving
the machine gravity drainage tube.
The drain tube must be positioned so that the water flows out freely, without possibility for the pipe to clog
up during the operation.
5.3 Water softener (optional)
The water softener for the mains water can be manual or automatic, depending on customer's request.
Before connecting the water softener to the coffee machine, the resins contained in it should be
washed off as described in the user's manual supplied with the appliance.
Note:
The water softener is considered an essential device to guarantee a proper operation of the espresso coffee
machine. A water softening system should be provided in order to guarantee the efficiency, performance and
duration of the components in the machine.
5.4 Installation of the water system
INTERNAl PUMP
1)
Use the braided 900 mm stainless-steel tube 32 to connect the on-off valve of the water supply to the
water softener inflow valve (figure 1).
2)
Using the rubber-braided 35 stainless-steel tube (2500 mm long), connect the internal pump intake with
the water softener valve (figure 2).
32
Figure 1
28
35
Figure 2