Troubleshooting Chart - Westward 3JR69A Manual De Instrucciones Operativas Y Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Westward Operating Instructions and Parts Manual
Compact Air Compressor
Voltage sources, moving parts, or compressed air sources
are exposed when repairing the compressor. Personal
injury can occur. Unplug the compressor before attempting any repairs.

Troubleshooting Chart

Symptom (s)
Possible Causes (s)
1.
Hose fitting loose.
Air Leaks
Compressor is not
1.
Prolonged excessive
use of air.
delivering enough air.
2.
Hole in hose.
3.
Air leaks.
Motor will not run.
1.
Fuse blown, circuit
breaker tripped.
Model 3JR69A
Corrective Actions (s)
1.
Tighten fitting.
1.
Decrease the amount
of air usage. Your
compressor is not
large enough for the
air requirement.
2.
Replace the hose.
3.
Tighten fittings.
1a. Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch
circuit.
b.
Check for proper
fuse. You should be
using a
"Time Delay" fuse.
c.
Check for low voltage
problem.
d.
Check the extension
cord.
e.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
14- ENG
Westward Operating Instructions and Parts Manual
Compact Air Compressor
Symptom (s)
Possible Causes (s)
Motor will not run
2.
Extension cord is
wrong length or
(continued)
gauge.
3.
Loose electrical
connections.
4.
Faulty motor.
High discharge
1.
Adjustable pressure
pressure. Cannot be
valve not functioning. 1.
adjusted lower.
Model 3JR69A
Corrective Actions (s)
2.
Check the extension
cord.
3.
Check wiring
connection inside
terminal box area.
4.
Contact a trained
service technician.
Risk of bursting.
DO NOT operate
the compressor if
this problem exists.
Adjustable pressure
valve must be
replaced.
15- ENG