Important Remarks; Declaration Of Conformity - V2 DEV-R1 Manual Del Usuario

Módulo de control miniatura para toldos y persianas
Ocultar thumbs Ver también para DEV-R1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Description
The DEV-R1 module allows to control a single phase
asynchronous motor for the automation of awnings and rolling
shutters.
The small size of the container allows the module to be easily
inserted inside the switches.
• Power supply with extended range: 85 ÷ 260 Vac - 50/60 Hz
• Very low power consumption in stand-by
• 434.15 MHz radio receiver with integrated antenna
• Compatible with DUO and ADLER series transmitters
• Stores up to 30 radio channels
• Two wired inputs: up and down
• Output to control a single phase asynchronous motor
• Integrated button for programming operations
• Wireless programming via a remote control provided with
memory
• Wireless management of HURRICANE-RS e TYPHOON series
weather sensors.
Specifications
Power supply ______________________ 85 ÷ 260 Vac - 50/60 Hz
Consumption in stand-by ____________ 0,25 W
Motor maximum power _____________ 500 W
Operating temperature ______________ -20 ÷ +60 °C
Maximum operating time ____________ 120 s

IMPORTANT REMARKS

• Attention: for people safety it is important to follow carefully
the instructions. Keep the instructions.
• Important safety instructions for the installation.
Attention: a wrong installation can cause serious accidents.
Follow carefully the installation instructions .
• This device can be installed only from qualified persons.
• The control buttons and the connection cables shall have
insulation properties suitable for electrical installations with
operating voltage of not less than 300Vac
• In order to protect the device, the installer must provide for a
magnetotermical differential switch (separation among the
contacts: at least 3 mm), ensuring the omnipolar sectioning
from the power supply.
• The device must be installed only inside a junction box
or wall box.
• The device container does not provide any protection against
water. Thus, it should be installed only in protected
environments.

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that DEV-R1 products conform to the
essential requirements established in the following directives:
- 2004/108/CEE (EMC Directive in accordance with standards
EN 61000-6-2, EN 61000-6-3 + EN 50336)
- 2006/95/CEE (Low Voltage Directive in accordance with
standards EN 60335-1 + EN 60335-2-97)
- 99/05/CEE (Radio Directive in accordance with standard
EN 301 489-3)
Racconigi, lì 14/06/2011
V2 S.p.A. legal representative.
Cosimo De Falco
WIRING
Motor up
q
Motor down
COM
Motor common
P1
Entry of button P1 (up control)
P2
Entry of button P2 (down control)
N
Power supply neutral
L
Power supply phase
NOTE: The motor direction (up/down) depends on the
position of the motor and wiring.
7

Publicidad

Tabla de contenido
loading

Tabla de contenido