ABIPLAS
CUT
Type
®
ABIPLAS
CUT 70/MT 70
®
ABIPLAS
CUT 110/MT 110
®
ABIPLAS
CUT 150/MT 150
Standard values
Tab. 10
Ein
CAUTION
Overtightening leads to thread damage.
3 Attaching the swirl ring
NOTE
• Ensure correct position
• The air holes should always be toward the electrode tip.
4 Attach selected plasma nozzle.
• Selection of the plasma nozzle is determined primarily by the thickness of
the material to be cut and the current intensity.
 see Tab. 4 on page EN-5
• The following standard values apply:
Plasma nozzle
Standard
Standard
Standard
long
long
Cross slot
Cross slot
Long cross slot
Standard
Standard
Standard
Standard
long
Long cross slot
Gouging
Standard
ø [mm]
Current intensity [A]
0,9
30
1,1
30-60
1,2
50-70
0,9
30
1,1
30-50
0,9
30
1,1
30-60
0,9
30
1,0
30-50
1,2
40-70
1,4
70-90
1,6
90-110
1,2
50
1,2
50
2,6
1,2
70