AHT Cooling Systems GmbH
1
General details
Before installing and starting up this cabinet, any
applicable rulings relating to trade law must be observed.
AHT
cabinets
formaldehyde, cadmium or substances which interfere
with
moistening.
The refrigerant R404A (44% R125, 4% R134a, 52%
R143a) is covered by the Kyoto Protocol and has a
global warming potential (GWP) of 3784.
The design of the individual appliance types may vary.
Airborne sound emissions of the units < 70 dB(A)
In the event of loud noises and/or strong vibrations in the
unit, contact a service technician.
The weights of the units are given in the datasheets.
They can be obtained from AHT.
2
Rating plate and serial number
The details provided on the rating plate must be
observed when installing and maintaining. This plate
can be found on the rear of the cabinet.
The serial number, cabinet type and refrigerant can be
found either on the rating plate or on the sticker affixed
to the inside plastic frame at the back.
3
Usage
AHT units are designed for storing pre-packaged,
frozen foods which have already been frozen to the
appropriate temperature and pre-packaged frozen ice
cream or frozen ice cream stored in suitable containers.
The cabinets are not suitable for freezing fresh
products. When putting goods into storage, please
ensure that the cabinets are set correctly.
AHT cabinets of the (U) and (S) model ranges have
been designed to store fresh, pre-chilled goods.
WARNING: Any form of cabinet usage which differs
from that described above is not intended
The storage of any type of bottles is considered to be im-
proper use for freezers. There is a danger of injury from
breakage. The awless condition of the refrigeration unit
and its proper use must be monitored regularly by the
B
Minimum spacing of appliances:
contain
no PCB, PCT, asbestos,
A
Spacing A =
Spacing B =
instructed operating staff. To that effect, the units must
be checked to make sure that products that have been
stored there by third parties (improperly) are removed.
WARNING: the models Barcelona, Boston, Berlin and
Oslo with double-glazed insulation (without capillary
pipe / valve) may only be installed in locations less
than 2000 m above sea level.
4
Unpacking and handling
WARNING: To prevent the cooling unit from damage,
it may only be transported and stored when in its
usage position. Non-observance of this requirement
will result in a loss of warranty.
A visual check must be undertaken before and during
unpacking of the cabinet to check for possible transport
damage. Please look for loose parts, buckling, scratches,
visible loss of fluid, etc.
Report any damage to AHT immediately (note "Rules
governing damage"). AHT's terms and conditions also
apply.
Please check for loose function parts before disposing of
the packaging material.
5
Installation
Install the cabinet horizontally in a well-ventilated
position.
Cooling units emit the heat they take from the
storage compartment into the surrounding air. Air
circulation around the cabinets should not
therefore be hindered.
Observe minimum spacing when installing in
blocks (see sketch)
The areas in between must not be covered
(Exception AHT cover or with AHT approval).
In the case of individual cabinets keep a min.
distance of 50 mm all round to neighbouring
surfaces (e.g.: walls).
Advertising may only be stuck on in the form of
thin films. Do not secure thick, insulating
materials to the outer panels.
0 mm
155mm/100mm
15
Detail "A"
Detail "B"