Tripp-Lite SMX Serie El Manual Del Propietario página 12

Ocultar thumbs Ver también para SMX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Guidance and Manufacturer's Declaration
Guidance and Manufacturer's Declaration—Electromagnetic Immunity
This Medical-Grade UPS is intended for use in the electromagnetic environment specified below. The customer
or the user of this Medical-Grade UPS should assure that it is used in such an environment.
Standard
EN 61000-4-2:2009
EN 61000-4-3: 2006
+A1:2008+A2:2010
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-4-4:2012
EN 61000-4-5:2006
EN 61000-4-6:2013
EN 61000-4-8:2010
EN 61000-4-11:2004 Voltage
EN 61000-2-2:2004
18-10-326-933821.indb 12
Description
Test Level/Limit
Electrostatic
±15 kV Air Discharge
Discharge
±8 kV Contact Discharge, VCP , HCP
Immunity
Radiated
10V/m, 80 - 1000 Mhz
Electromagnetic
3V/m, 1 to 2.7 GHz at 80% 1kHz AM
Immunity
Modulation
Radiated
RF wireless communication fields
Electromagnetic
on Spot Frequencies from Table 9 at
and Proximity
50%, Square wave Modulation 9 to
Fields Immunity
28 V/m,
Power
Class A
Harmonics
230V, 50/60Hz
Pst ≤ 1, dc ≤ 3.3%, dmax ≤ 6%,
Voltage
Fluctuation 230V,
d(t) ≤ 3.3% for 500ms
50Hz
Electrical Fast
±2kV on AC Mains
Transient/Burst
±1 kV on SIP/SOP Ports
Immunity
Surge Immunity
±0.5 kV, ±1 kV, ±2kV CM Line-Gnd
±0.5 kV, ±1 kV, DM Line-Line
NA on SIP/SOP Ports
Conducted
6V rms, on ISM and Amateur bands,
Immunity
3V rms, 0.15 - 80 MHz, AC Mains
and SIP/SOP Ports
Power Frequency
30A/m @ 50 Hz or 60 Hz
Magnetic Field
3 orthogonal orientations
Immunity
0%, 0.5 Cycles, 0%, 1 Cycle
Dips, Short
70%, 30 Cycles, 0%, 300 Cycles
Interruptions
and Voltage
Variations
Immunity
Power Line
Single sinusoidal source of 10V rms,
Harmonics and
slowly varied from 140 to 360 Hz.
Inter-Harmonics
Guidance
Floors should be wood,
concrete or ceramic tile.
If colors are covered with
synthetic material, the relative
humidity should be at least
30%.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Power frequency magnetic
fields should be at levels
characteristic of a typical
location in a typical
commercial or hospital
environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
12
11/7/2018 11:17:11 AM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Smx700hglSmx1200xlhglAg-031bAg-031c

Tabla de contenido