INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION
1.
GENERAL FEATURES
This crepuscular-timed switch board serves to control outside service lights. Four operating modes and a choice of
time settings enable you to control night lighting in a different way.
2.
TECHNICAL SPECIFICATIONS
2.1

Hardware specifications

Power supply
Max absorbed power
Outside lamps max. load
Operating ambient temperature
Protection fuse
Rapid connector
Terminal board inputs
Terminal board outputs
2.2

Operating parameters

Logic
Outside lights lighting up time
Light sensor sensitivity
3.
BOARD LAY-OUT (fig.1)
F1
Fuse F1 5x20 250mA/250V (mains circuit)
TF1
Transformer
FT1
Light sensor
TR1
Trimmer for adjusting sensitivity of light sensor
LD1
Light sensor control LED
J1
230VAC power supply input/output terminal board
J2
Rapid connector for decoding cards/5-pin RP receivers
J3
Lighting up push-button terminal board
DS1
Programming microswitches
T - 0.25A
F1
CREPUSCULAR-TIMED SWITCH BOARD
230 Vac mains power supply / Lighting up push-button /
TF1
J1
L N NO C (L)
230Vac - 50Hz
10VA
1500W
- 20°C + 55°C
mains circuit
for decoding cards or 5-pin RP receivers.
Input for pulse from control unit flashing lamp.
230 Vac 1500W max outside lights
4 Operating modes
programmable from 5 seconds to 10 minutes
adjustable with trimmer
ON
OFF
LD1
J3
4
1 2 3 4 5 6 7 8
DS1
+
TR1
-
FT1
J2
Fig. 1